Evidence map›Paper›PMID 41332951›Full record

ArticleJournal of dental research, dental clinics, dental prospects2025

Photoelastic analysis of stress distribution in single and three-unit implant-supported prostheses with different internal connections.

Abbas Zahoui, Marcelo Coelho Goiato, Rodrigo Antonio de Medeiros, Daniela Micheline Dos Santos, Marcio Campaner, Sandro Basso Bitencourt, Aldiéris Alves Pesqueira

Abstract read
In one paragraph

Article in Journal of dental research, dental clinics, dental prospects, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Abbas ZahouiFaculty of Dentistry, University Sagrado Coração - USC, Bauru, SP, Brazil.ORCID https://orcid.org/0000-0002-2955-8556
Marcelo Coelho GoiatoDepartment of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP, Araçatuba, São Paulo, Brazil.ORCID https://orcid.org/0000-0002-3800-3050
Rodrigo Antonio de MedeirosSchool of Health Sciences, University of Brasília, Brasília/DF, Brazil.
Daniela Micheline Dos SantosDepartment of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP, Araçatuba, São Paulo, Brazil.
Marcio CampanerDepartment of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP, Araçatuba, São Paulo, Brazil.
Sandro Basso BitencourtDepartment of Rehabilitative & Reconstructive Dentistry, School of Dentistry, University of Louisville, Louisville, KY.
Aldiéris Alves PesqueiraDepartment of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP, Araçatuba, São Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The accurate fit between the dental implant and the prosthetic abutment is crucial for the stability of the entire prosthetic-implant system, providing a better distribution of the occlusal load to the surrounding bone. To improve stress distribution between the implant and bone, various types of internal connection implants have been introduced. However, few studies are available on the biomechanical behavior of these connections. This study investigated the stress distribution in screwed implant-supported prosthesis with different implant‒abutment connections using a photoelastic analysis. Methods: Eight photoelastic models were fabricated in PL-2 resin and divided according to the different types of internal connections: Morse taper (MT), internal Morse hexagon (IMH), Morse taper hexagon (MTH), and frictional Morse taper (FMT) implants (3.75×11.5 mm), and the number of crowns (single and 3-unit pieces). Models were positioned in a circular polariscope, and 100-N axial and oblique (45º) loads were applied to the occlusal surface of the crowns using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using Adobe Photoshop software. Results: Under axial loading, the number and distribution of high-intensity fringes did not differ among groups for both crown types (single and splinted 3-element). Low stress values were noted at the implant apex. The oblique loading increased the number of fringes for all groups. In conclusion, the internal connection tested in this study did not affect the number and distribution of stress. Conclusion: The different types of internal connections provided better stability for the implant‒prosthesis set, which improved stress distribution when the prosthetic pillar was loaded, with the Morse cone friction system showing less stress. Oblique loading resulted in a higher stress concentration than axial loading.

Indexed as

BiomechanicsDental implantDental prosthesis

Identifiers

PMID41332951
PMCPMC12665962

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.