ArticleJournal of orthopaedic surgery and research2025
Anatomical landmarks and intraoperative "safe zone" for precise acetabular prosthesis placement in total hip arthroplasty for developmental dysplasia of the hip.
Article in Journal of orthopaedic surgery and research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundThe precise positioning of the acetabular prosthesis in total hip arthroplasty is critical, as it directly influences articulation with the femoral head prosthesis, hip biomechanics, and functional recovery. However, the absence of reliable anatomical landmarks for intraoperative guidance remains a significant challenge in achieving optimal implant orientation. This study aims to provide a theoretical and experimental basis for improving the accuracy of prosthesis implantation and supporting anatomical acetabular reconstruction in clinical practice.
methodsFrom September 2018 to December 2020, the pelvic three-dimensional CT data of 22 patients (36 hips) with DDH were collected in the orthopedics department of the First Affiliated Hospital of Bengbu Medical University. The CT data were imported into Mimics software for 3D reconstruction, and 1:1 scale pelvic models were fabricated using 3D printing technology. After restoring the morphology of the acetabular notch and fossa on the models, the acetabulum was reamed according to standard THA techniques. The inferior edge of the acetabular prosthesis was positioned 1-5 mm proximal and distal to the proximal line connecting the anterior and posterior acetabular notches (PLAPAN) to determine prosthesis inclination. The inferior edge of the acetabular prosthesis was rotated 1-5 mm pronating and supinating around the proximal point of the posterior acetabular notch (PPAPN) to determine prosthesis anteversion. The pelvis plain radiographs were taken, and the inclination and anteversion of the acetabular prosthesis were calculated at 22 positions. Statistical analysis was performed on the collected data.
resultsIn DDH, the intraoperative "safe zone" of acetabular prosthesis inclination in THA was (- 2 to + 1 mm), that is, the lower edge of the acetabular prosthesis was 2 mm proximal ~ 1 mm distal to the proximal line of the anterior and posterior acetabular notches (the average inclination of the acetabular prosthesis was (35.06 ± 3.35)°-(41.64 ± 3.51)°). The optimal inclination of the acetabular prosthesis could be obtained when the lower edge of the acetabular prosthesis was parallel to the proximal line of the anterior and posterior acetabular notches (the average inclination of the acetabular prosthesis was (41.64 ± 3.51)°). The intraoperative "safe zone" of acetabular prosthesis anteversion in THA is (- 2 to 0 mm), that is, the lower edge of the acetabular prosthesis was 2 mm supinating ~ 1 mm pronating at the proximal point of the acetabular posterior notch (the average anteversion of the acetabular prosthesis was (10.67 ± 4.55)°-(20.86 ± 4.44)°). The optimal anteversion of the acetabular prosthesis could be obtained when the lower edge of the acetabular prosthesis was 1 mm of supination at the proximal point of the acetabular posterior notch (the average anteversion of the acetabular prosthesis was (14.58 ± 3.83)°).
conclusionIn THA for DDH, the acetabular notch and fossa provide reliable anatomical landmarks for precise prosthesis placement. This study further establishes a defined intraoperative "safe zone" for the prosthesis inclination and anteversion, providing surgeons with a clear theoretical target to enhance procedural safety and reduce the risk of dislocation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.