Evidence map›Paper›PMID 41326877›Full record

ArticleJournal of imaging informatics in medicine2026

Automated HFrEF Diagnosis Using an Optimized TimeSformer Model in Echocardiography.

Georgios Petmezas, Vasileios E Papageorgiou, Vassilios Vassilikos, Efstathios Pagourelias, Dimitrios Tachmatzidis, George Tsaklidis, Aggelos K Katsaggelos, Nicos Maglaveras

Abstract read
In one paragraph

Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Georgios PetmezasSchool of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece. petmezgs@auth.gr.ORCID http://orcid.org/0000-0002-3371-569X
Vasileios E PapageorgiouDepartment of Mathematics, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Vassilios VassilikosSchool of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Efstathios PagoureliasSchool of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Dimitrios TachmatzidisSchool of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.
George TsaklidisDepartment of Mathematics, Aristotle University of Thessaloniki, Thessaloniki, Greece.
Aggelos K KatsaggelosDepartment of Electrical and Computer Engineering, Northwestern University, Evanston, IL, USA.
Nicos MaglaverasSchool of Medicine, Aristotle University of Thessaloniki, Thessaloniki, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heart failure with reduced ejection fraction (HFrEF) presents a significant diagnostic challenge, particularly in advanced stages. Deep learning (DL) models offer promising potential for automated HFrEF detection, but their effectiveness is often limited in small and imbalanced clinical datasets. In this study, we propose a novel approach to enhance HFrEF detection from echocardiographic videos. We adapt the TimeSformer architecture-a Transformer-based model optimized for spatiotemporal feature extraction in video data-and apply it for the first time in echocardiography. In addition, we introduce a domain-informed left ventricle (LV) masking method using image segmentation to guide model attention toward diagnostically critical regions, boosting overall performance. Our methodology is evaluated both directly on a large-scale benchmark dataset and on a smaller, specialized clinical dataset from our cardiology department after fine-tuning. Experimental results show that the proposed framework yields substantial performance gains: on the benchmark dataset, we observe a 3% improvement in both model accuracy and area under the curve (AUC), while on the specialized dataset, improvements reach 7% in accuracy and 30% in AUC values. Moreover, TimeSformer consistently outperforms conventional approaches after the implementation of fine-tuning and LV masking. These findings highlight a practical and generalizable strategy for improving automated HFrEF diagnosis, with strong implications for clinical decision support in data-scarce healthcare settings.

Indexed as

Deep LearningEchocardiographyHeart FailureImage Interpretation, Computer-AssistedAlgorithmsHumansStroke VolumeDeep learning (DL)EchocardiographyHeart failure with reduced ejection fraction (HFrEF)Left ventricle (LV) maskingSpatiotemporal TransformerTransfer learning

Identifiers

PMID41326877
PMCPMC13481916

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.