Evidence map›Paper›PMID 41323637›Full record

ArticleJSES reviews, reports, and techniques2026

A comparison between a patient-specific bone regenerative implant and the osteochondral allograft procedure in a Hill-Sachs lesion, a cadaveric study.

Michał S Gałek-Aldridge, Koen Willemsen, Sophie H Nelissen, Bart C H van der Wal, Jos Malda, Michel P J van den Bekerom, Arthur van Noort

Abstract read
In one paragraph

Article in JSES reviews, reports, and techniques, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Michał S Gałek-AldridgeDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
Koen WillemsenDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
Sophie H NelissenDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
Bart C H van der WalDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
Jos MaldaDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
Michel P J van den BekeromShoulder and Elbow Unit, Joint Research, Department of Orthopaedic Surgery, OLVG, Amsterdam, The Netherlands.
Arthur van NoortDepartment of Orthopaedic Surgery, Spaarne Gasthuis, Haarlem, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Anterior shoulder instability with >30% humeral bone loss is typically treated with an osteochondral allograft (OCA), though complications and reoperation rates remain high (20%-30%). New methods such as 3D printing are being researched to mitigate these results. This study compares the surface geometry and biomechanical integrity of a 3D-printed biodegradable, patient-specific bone regenerative implant (O3D) to traditional OCA in the treatment of Hill-Sachs lesions (HSLs). Methods: In 14 cadaveric shoulders, HSLs were created in a uniaxial biomechanical set-up and confirmed using imaging. The shoulders were randomized over 2 groups: group A, OCA surgery, and group B, magnesium phosphate-polycaprolactone 3D-printed implant (O3D). After the reconstruction of the HSLs, imaging was performed to measure surface morphology and articular congruence. Finally, uniaxial biomechanical testing was performed to measure postimplantation stability. Results: The average force needed to create a HSL was 1120 N. Implant surface area and joint surface area showed no significant difference between the groups ( Conclusion: Both OCA and O3D implants effectively restored joint integrity in large HSLs. The O3D implant showed superior congruence and equivalent biomechanical performance, illustrating a 3D-personalized, regenerative alternative to allografts.

Indexed as

3D-printed implantBiocompatible scaffold and joint preservationBone regenerationHill-Sachs lesionHumeral head reconstructionOsteochondral allograftShoulder instability

Identifiers

PMID41323637
PMCPMC12657296

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.