Evidence map›Paper›PMID 41323005›Full record

ArticleCureus2025

Improving Visual Field Testing Reliability by Using an Educational Patient Leaflet.

Basil Suresh, Sam Kathiramalai, Harikesh Kaneshayogan

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Basil SureshMedicine and Surgery, West Hertfordshire Teaching Hospitals NHS Trust, Watford, GBR.
Sam KathiramalaiMedicine and Surgery, West Hertfordshire Teaching Hospitals NHS Trust, Watford, GBR.
Harikesh KaneshayoganOphthalmology, West Hertfordshire Teaching Hospitals NHS Trust, Watford, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Reliability indices such as fixation losses (FL), false positives (FP), and false negatives (FN) determine the clinical utility of standard automated perimetry (SAP). Patient education can improve test performance, but low-cost, scalable approaches are needed. Our study aimed to evaluate whether a one-page patient leaflet delivered immediately before testing improves Humphrey Swedish Interactive Thresholding Algorithm (SITA) Fast 24-2 reliability. Methods We conducted a single-center, non-randomized quality-improvement study in glaucoma follow-up clinics. A total of 39 patients were included in this study. Each eye's most recent pre-leaflet SAP test was paired with its first post-leaflet SAP test under identical parameters (Humphrey Field Analyzer, SITA Fast 24-2, size III, 31.5 asb). The primary endpoint was composite "full reliability" (FL ≤10%, FP ≤10%, FN ≤10%) per eye, analyzed with McNemar's test and effects reported as the difference in paired proportions with 95% CI. Family-wise error across eyes was controlled by Holm-Bonferroni. The secondary endpoints were continuous changes in FL%, FP%, and FN% per eye, analyzed using the Wilcoxon signed-rank test with Hodges-Lehmann (HL) median change. Analyses were performed per eye without across-eye pooling, and only pairwise complete cases were used. This project was registered locally as a quality-improvement study and adhered to the principles outlined in the Declaration of Helsinki. Results  We analyzed 39 right and 37 left eyes (patient mean age: 66±15.5 years; mean inter-test interval 6.3 months). For our primary outcome of full reliability, the proportion of reliable tests increased from 31% to 54% in the right eye and from 41% to 65% in the left eye, with both remaining significant after Holm-Bonferroni. For our secondary outcome, FN% decreased significantly (right -4.5 pp and left -4.0 pp), while FL% declined in the right eye (-16.4 pp) with no significant change in the left. FP% showed small, non-significant increases. Conclusions A brief, one-page leaflet delivered immediately before SITA Fast testing increased the proportion of fully reliable fields and reduced false-negative responses in routine practice. This low-cost intervention is straightforward to implement and may reduce repeat testing. Confirmation under SITA Faster with a randomized design using visit-level endpoints is warranted.

Indexed as

glaucoma clinicglaucoma diagnosis and managementhumphrey analyzerhumphrey visual field perimetrypatient understandingquality improvement studystandard automated perimetryvisual field lossvisual field screeningvisual field testing

Identifiers

PMID41323005
PMCPMC12662638

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.