Evidence map›Paper›PMID 41322705›Full record

ArticleInternational journal of dentistry2025

Evaluation of Dimensional Stability in Four Types of Impression Materials Using Digital Analysis.

Hussein Ali M Hussein, Mohammed Alkhafagy, Amal Qasim Ahmed, Halah Abdulkareem A Alkhawaja, Fadhil Faez Sead

Abstract read
In one paragraph

Article in International journal of dentistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hussein Ali M HusseinDepartment of Prosthodontic, College of Dentistry, University of Kufa, Najaf, Iraq.ORCID https://orcid.org/0000-0002-3145-9637
Mohammed AlkhafagyDepartment of Prosthodontic, College of Dentistry, The Islamic University, Najaf, Iraq.ORCID https://orcid.org/0000-0003-4336-0340
Amal Qasim AhmedDepartment of Prosthodontic, College of Dentistry, University of Kufa, Najaf, Iraq.ORCID https://orcid.org/0000-0002-1624-3125
Halah Abdulkareem A AlkhawajaDepartment of Physiology, Jabir Ibn Hayyan University for Medical and Pharmaceutical Sciences, Faculty of Medicine, Najaf, Iraq.ORCID https://orcid.org/0000-0001-7940-3272
Fadhil Faez SeadDepartment of Prosthodontic, College of Dentistry, The Islamic University, Najaf, Iraq.ORCID https://orcid.org/0000-0002-8285-6026

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dimensional precision of casts is essential for the quality of fixed prosthesis therapy, with the impression technique being a crucial component affecting this precision. This in vitro study is to evaluate the dimensional precision of casts generated from four varieties of impression materials. Materials and Methods: Utilizing 20 specimens, four types of impression materials were fabricated and subsequently classified into four groups: condensation silicone impression material group (heavy and light body), condensation silicone impression material group (light body only), addition silicone impression material group (heavy and light body), and alginate impression material group. Dimensional stability was evaluated by acquiring imprints of an acrylic mold with three supports that replicate a slightly edentulous arch, which were then filled with stone. The stability was assessed by shooting photos with a Canon digital macro-lens camera, thereafter measuring the distances between the three posts using AutoCAD software (three lines were measured). Results: This study evaluated the dimensional precision of four frequently utilized impression materials in comparison to the primary standard. Dimensional accuracy was evaluated along three measurement lines, revealing substantial deviations from the standard for all materials ( Conclusion: In summary Although the digital technique may be more dependable and less complicated way to evaluate the qualities of impression materials, addition silicone heavy and light body demonstrated superior dimensional accuracy when compared with the other three impression materials. In contrast, among the four impression materials tested, condensation silicone heavy & light body had the largest dimensional shifts, indicating the lowest degree of dimensional accuracy.

Indexed as

AutoCAD softwaredimensional stabilityimpression materials

Identifiers

PMID41322705
PMCPMC12659973

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.