Evidence map›Paper›PMID 41321467›Full record

ArticleAmerican journal of preventive cardiology2025

Comparing the accuracy of continuous blood pressure monitoring using wearable cuffless devices with conventional 24-hour ambulatory blood pressure monitoring: A systematic review and meta-analysis.

Insun Lee, Min Jung Chang

Abstract read
In one paragraph

Article in American journal of preventive cardiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Insun LeeDepartment of Pharmacy and Yonsei Institute of Pharmaceutical Sciences, Yonsei University, Incheon, Republic of Korea.
Min Jung ChangDepartment of Pharmacy and Yonsei Institute of Pharmaceutical Sciences, Yonsei University, Incheon, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood pressure (BP) variability limits the reliability of office BP measurements, potentially leading to misdiagnosis and inappropriate hypertension management. Ambulatory blood pressure monitoring (ABPM) provides a comprehensive 24 h BP assessment but causes discomfort due to repeated cuff inflation. Continuous BP monitoring using wearable cuffless devices offers an alternative solution with improved patient comfort. This study evaluates the accuracy of continuous wearable cuffless BP device compared to conventional cuff-based ABPM through a systematic review and meta-analysis of studies published between October 2019 and September 2024. The primary outcome was mean 24 h BP, while secondary outcomes included mean daytime and nighttime BP. Subgroup analyses were conducted based on BP estimation technologies. Results showed comparable accuracy to conventional ABPM for daytime measurements, with mean differences (MD) within acceptable ranges for both systolic BP (SBP) (MD=-0.99 mmHg, 95 % confidence interval [CI]: -3.47, 1.49) and diastolic BP (DBP) (MD=0.70 mmHg, 95 % CI: -1.19, 2.58). However, notable discrepancies were observed for nighttime measurements, including both SBP (MD=4.48 mmHg, 95 % CI: 0.27, 8.69) and DBP (MD=5.64 mmHg, 95 % CI: 2.57, 8.71). Consequently, 24 h diastolic BP also showed significant differences (MD=2.10 mmHg, 95 % CI: 0.13, 4.08). Currently available wearable cuffless BP devices are not yet reliable for nighttime BP assessment-a critical limitation given nocturnal BP in cardiovascular risk stratification. Subgroup analysis revealed that photoplethysmography (PPG)-based devices demonstrated more favorable accuracy across all time intervals compared to other technologies; however, this finding should be considered exploratory and requires further validation in larger studies. Future research should focus on improving nighttime BP accuracy through enhanced calibration before these devices can be recommended for comprehensive 24 h BP monitoring in clinical practice.

Indexed as

Ambulatory blood pressure monitoring (ABPM)Cuffless BP monitorHypertensionMeta-analysisPhotoplethysmography (PPG)Systematic review

Identifiers

PMID41321467
PMCPMC12663680

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.