ArticleScientific reports2025
Optical fiber laser system for torsion measurement using a three-core fiber and a nanocrystal-based reflector.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
We report a novel and highly sensitive torsion sensor that integrates a multicore fiber (MCF) within a Sagnac interferometer so that the same MCF segment serves as both the reflective element and the sensing head of a fiber-ring laser. The laser architecture incorporates a distributed reflector implemented as a ZnGa₂O₄-nanocrystal-doped fiber section, which enhances overall system performance. The device exhibits high torsional responsivity over 0°-150°, with distinct behavior across sub-ranges: in 0°-50°, phase analysis yields a sensitivity of 0.08 rad/° with R² = 0.991; in 88°-150°, amplitude analysis-under the ring-laser configuration-shows an improvement in sensitivity from 0.2 to 0.5 dBm/° (R² = 0.995). In the intermediate interval (50°-88°) neither phase nor power varies monotonically, so a function-fitting neural network was employed to bridge this gap, achieving a root-mean-square error of 0.06°. The system attains an angular resolution of 0.8°, ensuring accurate torsion estimation across the entire measurement span.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.