Evidence map›Paper›PMID 41317191›Full record

ArticleChild's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery2025

Adaptation and validation of a collaborative robotic equipment applied to pediatric neurosurgery.

Allison Roberto da Silva, Hélio Rubens Machado, Marcelo Volpon Santos, Glauco Augusto de Paula Caurin, Calvin Suzuki de Camargo

Abstract readValidation Study
PubMed Publisher
In one paragraph

Article in Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Allison Roberto da SilvaUniversity Hospital, Ribeirão Preto Medical School, University of São Paulo, São Paulo, Brazil. alrsilva@hcrp.usp.br.
Hélio Rubens MachadoRibeirão Preto Medical School, University of São Paulo, Medicine School of São Paulo University, São Paulo, Brazil.
Marcelo Volpon SantosRibeirão Preto Medical School, University of São Paulo, São Paulo, Brazil.
Glauco Augusto de Paula CaurinUniversity of São Paulo, São Paulo, Brazil.
Calvin Suzuki de CamargoUniversity of São Paulo, São Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe first robotic surgery in history took place in 1987 using the PUMA 200 robotic arm. Since then, several devices have been developed, but widespread availability is still hindered by their high cost, especially in public funded hospitals.

objectiveConception and validation of a collaborative robotic equipment for the neurosurgical treatment of pharmacoresistant epilepsy.

methodsThis is a methodological study in which an industrial equipment was adapted and validated for neurosurgical application. Realistic tests and simulations were performed on complex, patient-specific, three-dimensional models, both in the laboratory and in the surgical environment. Such validation followed the criteria established by the FDA manual for certification of medical devices.

resultsPrecision tests analyzed the accuracy between the programmed and executed data, resulting in a mean error at the entry point of 2.21 mm and a target error of 4.41 mm. DISCUSSION: Comparative studies have pointed out the advantages of robotic over conventional surgeries, such as lower risk of bleeding, reduced surgical time, faster recovery, and excellent precision. Nevertheless, commercial challenges remain, mostly related to the high costs of software, hardware, and maintenance of currently used robots. The device described herein could be an affordable option.

conclusionThe KUKA IIWA SERIES® robot was adapted after successful simulations in the laboratory and operation room. The equipment was successfully tested, with trajectory errors within an acceptable margin, thus becoming a viable addition to enhance surgical precision. Future steps include approval by the respective government agency and further application in real operations.

Indexed as

Drug Resistant EpilepsyNeurosurgical ProceduresRobotic Surgical ProceduresStereotaxic TechniquesBrazilChildComputer SimulationElectrodes, ImplantedFeasibility StudiesHumansNeurosurgeryPediatricsSoftwareEpilepsyEpilepsy surgeryNeurosurgeryRobotic surgery

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked