Evidence map›Paper›PMID 41314447›Full record

ArticleActa biomaterialia2026

Effect of stent-graft compliance on hemodynamics and aortic stiffening in an in vivo porcine study.

Ramin Shahbad, Sivapriya Kuniyil, Alexey Kamenskiy, Elizabeth Zermeno, Kaspars Maleckis, Jason MacTaggart, Anastasia Desyatova

Abstract read
In one paragraph

Article in Acta biomaterialia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Windkessel Preserving Aortic Stent Graft Attenuates Left Ventricular Remodelling after Thoracic Endovascular Aortic Repair in a Porcine Model.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026
    Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ramin ShahbadDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States.
Sivapriya KuniyilDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States.
Alexey KamenskiyDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States.
Elizabeth ZermenoDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States.
Kaspars MaleckisDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States.
Jason MacTaggartDepartment of Surgery, University of Nebraska Medical Center, Omaha, NE, United States. Electronic address: jmactaggart@unmc.edu.
Anastasia DesyatovaDepartment of Biomechanics, University of Nebraska Omaha, Omaha, NE, United States. Electronic address: adesyatova@unomaha.edu.

Funding

Tissue Analysis Core (TAC)P20GM152301 · NIGMS · UNIVERSITY OF NEBRASKA OMAHA · PI Alexey Kamenskiy · 2024 to 2026
$8.8M
Effects of aortic compliance and Windkessel reduction on cardiac and aortic pathophysiologyR01HL147128 · NHLBI · UNIVERSITY OF NEBRASKA OMAHA · PI DESYATOVA, ANASTASIA S · 2019 to 2023
$3.0M
Localized Chelation Therapy for Removing Calcification in PADR01HL180371 · NHLBI · UNIVERSITY OF NEBRASKA OMAHA · PI John F Eberth, Alexey Kamenskiy · 2025 to 2026
$1.3M
NHLBI NIH HHS R01 HL147128NHLBI NIH HHS R01 HL180371NIGMS NIH HHS P20 GM152301
6 · The paper itself

Abstract

backgroundCompliance mismatch is a key contributor to adverse vascular remodeling and long-term hemodynamic complications following endovascular aortic repair. However, few in vivo studies have systematically compared the biomechanical and hemodynamic impacts of compliant versus conventional stent-grafts.

objectivesIn this study, we evaluated an elastomeric nanofibrillar stent-graft (NF-SG) against a commercially available stiff stent-graft (CS-SG) in a swine model, focusing on the effect of stent-graft type on the hemodynamic indices.

methodsTwenty Yucatan minipigs were divided into three groups: Control, CS-SG, and NF-SG. The latter two underwent endovascular implantation of the stent-grafts. Hemodynamic assessments were conducted at baseline, immediately post-implantation, and at 18-week follow-up. Local PWV, pressure, pulsatility, distensibility, and harmonic waveform analyses were performed at the ascending and descending thoracic aorta.

resultsCS-SG implantation led to a significant increase in PWV (from 4.72 to 7.66 m/s), marked reductions in aortic pulsatility at the stented site (from 6.4% to 1.7%), as well as suppressed harmonic contribution (from 39.3% to 29.3%) and distortion (from 0.12 to 0.05), indicating impaired distal impedance regulation. In contrast, the NF-SG preserved baseline PWV (4.69 to 5.37 m/s) and maintained physiological waveform profiles, with minimal changes in harmonic contribution and distortion. NF-SG also showed a smaller reduction in pulsatility at the stented site (from 6.1% to 3.1%).

conclusionsThese findings demonstrate that NF-SG exhibits superior biomechanical compatibility by preserving aortic compliance and normal hemodynamic function. Compliant stent-grafts may offer a promising strategy to reduce the long-term cardiovascular burden associated with conventional endovascular repairs. STATEMENT OF SIGNIFICANCE: Compliance mismatch is a significant challenge in endovascular aortic repair, contributing to adverse remodeling and long-term hemodynamic complications. Despite its clinical importance, few in vivo studies have systematically compared the biomechanical and hemodynamic impacts of compliant versus conventional stent-grafts. To address this gap, we performed a longitudinal study in a porcine model, comparing the performance of an innovative elastomeric nanofibrillar stent-graft with that of a commercially available stiff stent-graft. We demonstrate that implantation of the stiff stent-graft led to significant and sustained increases in pulse wave velocity, reduced aortic pulsatility, and impaired distal impedance regulation. In contrast, our elastomeric stent-graft preserved physiological aortic compliance and hemodynamic function, with minimal disruption to harmonic waveform profiles and distal pulsatility. These findings suggest that compliant stent-grafts may offer a promising strategy to reduce the long-term cardiovascular burden associated with conventional endovascular repairs.

Indexed as

AortaAorta, ThoracicBlood Vessel ProsthesisHemodynamicsStentsVascular StiffnessAnimalsComplianceSwineSwine, MiniaturePulse wave velocityStent-Graft complianceSwineThoracic endovascular aortic repair (TEVAR)Windkessel effect

Identifiers

PMID41314447
PMCPMC12805950

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.