ArticleActa biomaterialia2026
Effect of stent-graft compliance on hemodynamics and aortic stiffening in an in vivo porcine study.
Article in Acta biomaterialia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Revisiting the tension-free paradigm: Axially prestretched elastomeric nanofibrillar grafts restore artery-like axial biomechanics in a preclinical model.Acta biomaterialia · 2026Article
- Stent-graft compliance modulates regional mechanical and structural remodeling of the aorta.Acta biomaterialia · 2026Article
- Windkessel Preserving Aortic Stent Graft Attenuates Left Ventricular Remodelling after Thoracic Endovascular Aortic Repair in a Porcine Model.European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2026Article
- 2025 report on advances in thoracic aortic disease research.Journal of thoracic disease · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundCompliance mismatch is a key contributor to adverse vascular remodeling and long-term hemodynamic complications following endovascular aortic repair. However, few in vivo studies have systematically compared the biomechanical and hemodynamic impacts of compliant versus conventional stent-grafts.
objectivesIn this study, we evaluated an elastomeric nanofibrillar stent-graft (NF-SG) against a commercially available stiff stent-graft (CS-SG) in a swine model, focusing on the effect of stent-graft type on the hemodynamic indices.
methodsTwenty Yucatan minipigs were divided into three groups: Control, CS-SG, and NF-SG. The latter two underwent endovascular implantation of the stent-grafts. Hemodynamic assessments were conducted at baseline, immediately post-implantation, and at 18-week follow-up. Local PWV, pressure, pulsatility, distensibility, and harmonic waveform analyses were performed at the ascending and descending thoracic aorta.
resultsCS-SG implantation led to a significant increase in PWV (from 4.72 to 7.66 m/s), marked reductions in aortic pulsatility at the stented site (from 6.4% to 1.7%), as well as suppressed harmonic contribution (from 39.3% to 29.3%) and distortion (from 0.12 to 0.05), indicating impaired distal impedance regulation. In contrast, the NF-SG preserved baseline PWV (4.69 to 5.37 m/s) and maintained physiological waveform profiles, with minimal changes in harmonic contribution and distortion. NF-SG also showed a smaller reduction in pulsatility at the stented site (from 6.1% to 3.1%).
conclusionsThese findings demonstrate that NF-SG exhibits superior biomechanical compatibility by preserving aortic compliance and normal hemodynamic function. Compliant stent-grafts may offer a promising strategy to reduce the long-term cardiovascular burden associated with conventional endovascular repairs. STATEMENT OF SIGNIFICANCE: Compliance mismatch is a significant challenge in endovascular aortic repair, contributing to adverse remodeling and long-term hemodynamic complications. Despite its clinical importance, few in vivo studies have systematically compared the biomechanical and hemodynamic impacts of compliant versus conventional stent-grafts. To address this gap, we performed a longitudinal study in a porcine model, comparing the performance of an innovative elastomeric nanofibrillar stent-graft with that of a commercially available stiff stent-graft. We demonstrate that implantation of the stiff stent-graft led to significant and sustained increases in pulse wave velocity, reduced aortic pulsatility, and impaired distal impedance regulation. In contrast, our elastomeric stent-graft preserved physiological aortic compliance and hemodynamic function, with minimal disruption to harmonic waveform profiles and distal pulsatility. These findings suggest that compliant stent-grafts may offer a promising strategy to reduce the long-term cardiovascular burden associated with conventional endovascular repairs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.