Evidence map›Paper›PMID 41313183›Full record

ArticleJMIR diabetes2025

Toward a Personalized Basal Tuner for Detecting Basal Rate Inaccuracies in Type 1 Diabetes Mellitus Without Meal Data: Algorithm Development and Retrospective Validation Study.

Daniel Gasca Garcia, Hood Thabit, Paul W Nutter, Simon Harper

Abstract read
In one paragraph

Article in JMIR diabetes, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Daniel Gasca Garcia *Department of Computer Science, University of Manchester, Kilburn Building, Oxford Rd, Manchester, M13 9PL, United Kingdom, 44 7565135239.ORCID http://orcid.org/0000-0002-3944-3234
Hood Thabit *Division of Diabetes, Endocrinology and Gastroenterology, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, United Kingdom.ORCID http://orcid.org/0000-0001-6076-6997
Paul W Nutter *Department of Computer Science, University of Manchester, Kilburn Building, Oxford Rd, Manchester, M13 9PL, United Kingdom, 44 7565135239.ORCID http://orcid.org/0000-0003-4075-861X
Simon Harper *Department of Computer Science, University of Manchester, Kilburn Building, Oxford Rd, Manchester, M13 9PL, United Kingdom, 44 7565135239.ORCID http://orcid.org/0000-0001-9301-5049

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Basal rate (BR) adjustment is crucial for managing type 1 diabetes mellitus, accounting for 30% to 50% of total daily insulin needs. All current closed-loop systems revert to the user's usual pump BR (known as manual mode) in the event of closed loop failure. Furthermore, access to closed-loop systems remains relatively low in low- and middle-income countries and among those without suitable health insurance. Accurately adjusting the BR remains challenging, leading to hypo- or hyperglycemia, and research on optimizing the BR is limited. Objective: This study proposed an adaptive algorithm that uses continuous glucose monitoring data to identify BR inaccuracies without requiring meal intake information. Methods: The OhioT1DM dataset formed the basis for implementing this methodology. Each composite day was generated by excluding bolus insulin profiles lacking meal intake information and by calculating hourly blood glucose (BG) relative levels along with their corresponding reliability measures, enabling assessment of deviations from the recommended BR (ie, a BG relative change of 0 mg/dL). Both a noninferiority analysis and a classification precision metric were used to assess the practicality of this approach compared to using meal data. Results: Data from 12 participants showed noninferiority of the no-meal method: using a 20% noninferiority margin on absolute BG relative change, 9 of 12 participants met the criterion (1-sided P<.05). Classification precision was 73.9% (139/188) of meals correctly classified on average per participant (SD 11.8%; 95% CI 67.2%-79.7%). The daily cumulative BG average was 200.6 mg/dL (SD 61.7 mg/dL; 11.1 mmol/L, SD 3.4 mmol/L; 95% CI 161.4-239.8 mg/dL), with peak values reaching 270.15 mg/dL (14.99 mmol/L). Furthermore, 99.3% (286/288) of the BG relative values (SD 0.5%; 95% CI 97.5%-99.8%) that were unaffected by external factors were associated with incorrect BR settings, with deviations ranging from -25.5 to 46 mg/dL (-1.58 to 2.59 mmol/L). Conclusions: Current strategies to optimize BR settings are inadequate, and our approach of a personalized basal tuner (PBT) helps better analyze BR without relying on meal intake information. Indeed, without an optimally set BR, in the event of the closed loop reverting to manual mode, patients may be exposed to persistent hypo- or hyperglycemia, leading to safety and efficacy issues. Future work will focus on generating BR recommendations through the application of this algorithm in clinical practice to assist clinicians in setting BR in low- and middle-income countries, where closed-loop systems are not prevalent, to help increase time in range.

Indexed as

adaptive basal insulinblood glucose managementmeal detectionPBTpersonalized basal tunerT1DMtype 1 diabetes mellitus

Identifiers

PMID41313183
PMCPMC12661609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.