ArticleSkeletal radiology2026
Accuracy and reliability of 2D and 3D femoral version measurements on CT scans of 3D-printed haptic femur models: which method is most robust to changes in hip position?
Article in Skeletal radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesTo compare the accuracy and reliability of 2D and 3D methods for measuring femoral version against an anatomic reference standard using 3D-printed femoral phantoms.
methodsCT data from three skeletally mature pediatric patients (2 females, 1 male; age 17.8 ± 0.1 years) were used as digital templates for 3D-printed haptic femur models. The anatomic reference standard for femoral version was determined by an established drilling technique. Models underwent CT scanning in neutral position and variations of flexion, internal/external rotation, and abduction/adduction (in increments of 15°, 30°, 45°). Two radiologists measured femoral version on axial datasets using 2D techniques (Murphy, Lee, Reikerås) and a 3D-reconstructed model in a blinded fashion. Mean absolute error (MAE) between measurements and the reference standard and mean absolute differences (MAD) between readers were calculated.
resultsAcross all positions in all femurs, MAE was 22.9° ± 23.7° for the Murphy technique, 12.1° ± 8.5° for the Lee technique, 12.2° ± 9.6° for the Reikerås technique, and 2.3° ± 1.3° for the 3D method. For all 2D methods, MAE was greatest with adduction, flexion, and combinations of both. For the 3D method, femur position had no impact on MAE. MAD between readers was 9.7° for the Murphy technique, 4.7° for the Lee technique, 4.4° for the Reikerås technique, and 2.9° for the 3D method.
conclusionsFemoral version measurements based on 3D reconstructions are more accurate than traditional 2D techniques, more robust to femur positioning, and more consistent between readers. Accurate measurement of femoral version is important for understanding and treating lower extremity deformities in the skeletally mature pediatric population.