Evidence map›Paper›PMID 41307984›Full record

ArticleJournal of synchrotron radiation2026

The Single-Particle, Clusters and Biomolecules and Serial Femtosecond Crystallography instrument of the European X-ray Free-Electron Laser: Interaction Region Downstream at atmospheric pressure (IRD).

Adam Round, Piere Aller, Richard J Bean, Johan Bielecki, Agata Butryn, Nicholas Devenish, Raphael de Wijn, Thomas Dietze, Katerina Doerner, Fabio Dall'Antonia and 35 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

45 authors.

Adam RoundEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-0723-8228
Piere AllerDiamond Light Source, Diamond House, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.ORCID 0000-0002-1793-7030
Richard J BeanEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Johan BieleckiEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-3012-603X
Agata ButrynDiamond Light Source, Diamond House, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.
Nicholas DevenishDiamond Light Source, Diamond House, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.
Raphael de WijnEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-8342-1008
Thomas DietzeEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Katerina DoernerEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Fabio Dall'AntoniaEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Pontus FischerCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Gabriele GiovanettiEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-4804-7006
Sebastian GuentherCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0002-7329-6653
Huijong HanEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-1197-3014
Vincent HennickeCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0002-2997-2722
Chan KimEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0003-4559-7982
Yoonhee KimEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0001-9209-9500
Marco KloosEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-8745-9740
Jayanath C P KoliyaduEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Gabriel LeenPolyPico Technologies Ltd, Unit 10, Airways Technology Park, Rathmacullig West, Ballygarvan, Cork T12 DY95, Ireland.ORCID 0000-0003-2448-4428
Romain LetrunEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-0569-5193
Luis Lopez MorilloEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Allen M OrvilleDiamond Light Source, Diamond House, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.ORCID 0000-0002-7803-1777
Tim PakendorfCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Marco RamilliEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Nadja ReimersEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Patrick ReinkeCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Juan Sanchez-WeatherbyDiamond Light Source, Diamond House, Harwell Science and Innovation Campus, Didcot OX11 0DE, United Kingdom.ORCID 0000-0001-5893-9641
Tokushi SatoEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0003-3155-3487
Robin SchubertEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-6213-2872
Joachim SchulzEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-9310-8832
Cedric Signe TakemEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Marcin SikorskiEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Prasad ThuteEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Fabian TrostEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0001-5628-598X
Oleksii TurkotEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0001-5352-7744
Patrik VagovičCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.
Mohammad VakiliEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0001-9776-0177
Raul Villanueva GuerreroEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Henry N ChapmanCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0002-4655-1743
Alke MeentsCenter for Free Electron Laser Science CFEL, Deutsches Elektronen-Synchrotron DESY, Notkestrasse 85, 22607 Hamburg, Germany.ORCID 0000-0001-6078-4095
Serguei MolodtsovEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Sakura PascarelliEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.
Thomas TschentscherEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0002-2009-6869
Adrian P MancusoEuropean XFEL, Holzkoppel 4, 22869 Schenefeld, Germany.ORCID 0000-0003-1710-8969

Funding

Australian Research Council Centre of Excellence in Advanced Molecular Imaging CE140100011Bundesministerium für Bildung und Forschung 05E13GU1Bundesministerium für Bildung und Forschung 05K13GU7National Science Foundation, BioXFEL Science and Technology Center STC-1231306Royal Society RSWF/R2/182017Vetenskapsrådet 822-2013-2014Wellcome Trust
6 · The paper itself

Abstract

The Single-Particle, Clusters and Biomolecules and Serial Femtosecond Crystallography (SPB/SFX) scientific instrument at the European X-Ray Free-Electron Laser (EuXFEL) became operational with user experiments in September 2017. The unique properties and capabilities of the EuXFEL, enabling megahertz data collection rates, provide more rapid data collection with improved statistics compared with other XFEL facilities. This improves the feasibility of obtaining multiple data points in time-resolved experiments and hence enables the observation of reactions in greater detail (molecular movies). In collaboration with the SFX User Consortium (SFX UC), the SPB/SFX instrument was designed to further increase user access and research outcomes. Focusing the pulses downstream of the first interaction region [described previously (Mancuso et al., 2019)], a second experiment plane is enabled, which allows for greater optimization and more efficient usage of available beam time. Additionally, the SFX UC provided further instrumentation to provide improved capabilities on SPB/SFX. The aim for additional and extended functionality for the second interaction region was to enable sample-efficient data collection at atmospheric pressure in an environment where the sample temperature and humidity can be controlled. This paper describes the extended capabilities of the downstream interaction region of the SPB/SFX instrument and its major components, in particular its X-ray focusing optics, vacuum to atmospheric pressure out-coupling, available sample delivery methods and 2D detector, and the supporting optical laser systems for pump-probe experiments.

Indexed as

crystallographyfemtosecond experimentsXFELsX-ray free-electron lasers

Identifiers

PMID41307984
PMCPMC12809452

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.