Evidence map›Paper›PMID 41306947›Full record

ReviewJournal of medicine and life2025

Complications in cochlear implant surgery: a comprehensive review.

Cristian Mircea Neagoș, Bianca Gabriela Nenec, Adriana Neagoș, Anca Sin

Abstract readReview
In one paragraph

Review in Journal of medicine and life, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Cristian Mircea NeagoșOtorinologic Department, George Emil Palade University of Medicine, Science, and Technology, Târgu Mureș, Romania.
Bianca Gabriela NenecENT Department, Târgu Mureș Emergency County Hospital, Târgu Mureș, Romania.
Adriana NeagoșOtorinologic Department, George Emil Palade University of Medicine, Science, and Technology, Târgu Mureș, Romania.
Anca SinENT Department, Târgu Mureș Emergency County Hospital, Târgu Mureș, Romania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cochlear implantation is an established surgical intervention for patients with severe to profound sensorineural hearing loss. Although technological advancements have improved surgical outcomes, complications can still arise, affecting both short- and long-term postoperative results. Identifying and managing these complications is very important for optimizing patient outcomes. This review examined the key complications associated with cochlear implantation, discussing their mechanisms, clinical implications, and management strategies based on current literature. A comprehensive literature review was conducted using relevant studies from PubMed and other scientific databases. Key topics include intraoperative complications such as cerebrospinal fluid (CSF) leakage and electrode misplacement, as well as postoperative complications like intracochlear fibrosis, foreign body reactions, vestibular dysfunction, device extrusion, and infections, including otitis media and cholesteatoma. Despite being a generally safe procedure, cochlear implantation presents a range of complications, with incidence rates varying between pediatric and adult populations. Preoperative imaging and patient selection have an essential role in minimizing intraoperative risks such as CSF leakage, particularly in cases with inner ear malformations. Postoperative complications, including electrode migration, fibrosis, and vestibular dysfunction, can impact hearing outcomes and quality of life. Furthermore, late complications such as chronic infections and device extrusion require long-term follow-up and, in some cases, revision surgery. Cochlear implantation is a highly effective auditory rehabilitation technique with a favorable safety profile. However, complications-ranging from minor surgical site infections to major device failures-necessitate ongoing clinical vigilance. Future advancements in electrode design, surgical techniques, and biocompatible materials hold promise for reducing complications and improving patient safety.

Indexed as

Cochlear ImplantationCochlear ImplantsPostoperative ComplicationsHumanscochlear implantforeign body reactionGusher Syndromeimplant extrusioninner ear malformationsintracochlear fibrosisintracochlear inflammationotitis media

Identifiers

PMID41306947
PMCPMC12646197

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.