Evidence map›Paper›PMID 41305779›Full record

ArticleMedicine2025

Clinical efficacy and finite element analysis of dynamic crossing screw system in the treatment of non-displaced femoral neck fractures in elderly patients with osteoporosis.

Xiaolei Sheng, Jiayu Qian, Zhi Xu, Yi Zhu, Weiping Sha, Shoujin Tian, Yunzhong Huang, Jianfei Ge

Abstract read
In one paragraph

Article in Medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xiaolei ShengDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Jiayu QianEmergency Intensive Care Unit, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Zhi XuDepartment of Orthopedic, Zhangjiagang fifth People's Hospital, Zhangjiagang, Jiangsu Province, China.
Yi ZhuDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Weiping ShaDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Shoujin TianDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Yunzhong HuangDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.
Jianfei GeDepartment of Orthopaedic Surgery, Zhangjiagang Hospital Affiliated to Soochow University (Zhangjiagang First People's Hospital), Zhangjiagang, Jiangsu Province, China.ORCID 0009-0006-0735-3759

Funding

Suzhou Key Clinical Disease Diagnosis and Treatment Technology Special Project LCZX202330Suzhou Medical and Health Science and Technology Innovation Project SKYD20022048
6 · The paper itself

Abstract

Controversy persists regarding the optimal fixation approach for non-displaced femoral neck fractures in elderly osteoporotic patients. While clinical experience with femoral neck system (FNS) is growing, biomechanical validation remains incomplete. This retrospective study included 80 elderly osteoporotic patients with non-displaced femoral neck fractures treated from 2019 to 2024 - 40 with FNS and 40 with CCS. We evaluated healing time, hip function, pain levels, and complications. Additionally, finite element models constructed from computed tomography (CT) scans of an elderly osteoporotic volunteer compared the biomechanical performance of both fixation methods in Garden I and II fracture patterns. FNS patients demonstrated faster healing and superior functional outcomes at 6 months. Complications including femoral neck shortening and fixation failure occurred less frequently with FNS. Finite element analysis revealed lower stress concentrations at the fracture site with FNS compared to CCS, indicating better mechanical stability. FNS showed advantages over conventional cannulated screws in this patient population, achieving faster healing, improved function, and reduced complications.

Indexed as

Bone ScrewsFemoral Neck FracturesFracture Fixation, InternalOsteoporosisOsteoporotic FracturesAgedAged, 80 and overBiomechanical PhenomenaFemaleFinite Element AnalysisFracture HealingHumansMaleRetrospective StudiesTomography, X-Ray ComputedTreatment Outcomeagedbone screwsfemoral neck fracturesfinite element analysisinternal fixatorsosteoporosis

Identifiers

PMID41305779
PMCPMC12643719

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.