Evidence map›Paper›PMID 41305302›Full record

ReviewSensors (Basel, Switzerland)2025

Overview of Monitoring, Diagnostics, Aging Analysis, and Maintenance Strategies in High-Voltage AC/DC XLPE Cable Systems.

Kazem Emdadi, Majid Gandomkar, Ali Aranizadeh, Behrooz Vahidi, Mirpouya Mirmozaffari

Abstract readReview
In one paragraph

Review in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kazem EmdadiDepartment of Electrical Engineering, Sav. C., Islamic Azad University, Saveh 39197-15179, Iran.
Majid GandomkarDepartment of Electrical Engineering, Sav. C., Islamic Azad University, Saveh 39197-15179, Iran.
Ali AranizadehDepartment of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran 3715879817, Iran.
Behrooz VahidiDepartment of Electrical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran 3715879817, Iran.ORCID 0000-0002-9430-9468
Mirpouya MirmozaffariDepartment of Industrial Engineering, Dalhousie University, 5269 Morris Street, Halifax, NS B3H 4R2, Canada.ORCID 0000-0003-2679-0488

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-voltage (HV) cable systems-particularly those insulated with cross-linked polyethylene (XLPE)-are increasingly deployed in both AC and DC applications due to their excellent electrical and mechanical performance. However, their long-term reliability is challenged by partial discharges (PD), insulation aging, space charge accumulation, and thermal and electrical stresses. This review provides a comprehensive survey of the state-of-the-art technologies and methodologies across several domains critical to the assessment and enhancement of cable reliability. It covers advanced condition monitoring (CM) techniques, including sensor-based PD detection, signal acquisition, and denoising methods. Aging mechanisms under various stressors and lifetime estimation approaches are analyzed, along with fault detection and localization strategies using time-domain, frequency-domain, and hybrid methods. Physics-based and data-driven models for PD behavior and space charge dynamics are discussed, particularly under DC conditions. The article also reviews the application of numerical tools such as FEM for thermal and field stress analysis. A dedicated focus is given to machine learning (ML) and deep learning (DL) models for fault classification and predictive maintenance. Furthermore, standards, testing protocols, and practical issues in sensor deployment and calibration are summarized. The review concludes by evaluating intelligent maintenance approaches-including condition-based and predictive strategies-framed within real-world asset management contexts. The paper aims to bridge theoretical developments with field-level implementation challenges, offering a roadmap for future research and practical deployment in resilient and smart power grids. This review highlights a clear gap in fully integrated AC/DC diagnostic and aging analyses for XLPE cables. We emphasize the need for unified physics-based and ML-driven frameworks to address HVDC space-charge effects and multi-stress degradation. These insights provide concise guidance for advancing reliable and scalable cable assessment.

Indexed as

condition-based maintenancehigh-voltage cable systemsHVDC diagnosticsmachine learning in fault analysispartial discharge detectionXLPE insulation aging

Identifiers

PMID41305302
PMCPMC12656247

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.