Evidence map›Paper›PMID 41305269›Full record

ArticleSensors (Basel, Switzerland)2025

Improved Edge Pixel Resolution in Modular PET Detectors with Partly Segmented Light Guides.

Henry Maa-Hacquoil, Harutyun Poladyan, Brandon Baldassi, Borys Komarov, Janos Rado, Oleksandr Bubon, Alla Reznik

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Henry Maa-HacquoilDepartment of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada.
Harutyun PoladyanDepartment of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada.ORCID 0000-0002-1671-2761
Brandon BaldassiRadialis Inc., Thunder Bay, ON P7A 7T1, Canada.
Borys KomarovRadialis Inc., Thunder Bay, ON P7A 7T1, Canada.
Janos RadoDepartment of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada.
Oleksandr BubonDepartment of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada.
Alla ReznikDepartment of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada.

Funding

Canada Research Chair program N/ACIHR N/AMitacs IT30395Natural Sciences and Engineering Research Council of Canada Discovery and Alliance programs N/AOntario Institute for Cancer Research N/AOntario Research Fund: Research Excellence N/ATerry Fox Foundation and Research Institute N/A
6 · The paper itself

Abstract

backgroundThe asymmetric distribution of optical photons near the edges of Positron Emission Tomography (PET) sensor modules introduces errors in the coordinate reconstruction of scintillation events when center-of-gravity (CoG) algorithms are utilized. This issue, sometimes referred to as the "edge effect", results in overlap of crystal pixel signatures in flood maps and potential image artifacts in reconstructed PET images.

methodsPartly segmented 5 mm thick borosilicate light guides with slits cut parallel to the edges are filled with barium sulfate to restrict the spread of optical photons near the edges of the light guide. Data acquisitions are performed using single PET sensor modules in coincidence, both with single and multiplexed channel readout. CoG and truncated center-of-gravity (TCoG) methods are used for coordinate reconstruction.

resultsA 22 × 22 array of crystal signatures are distinguishable on crystal flood maps produced using sensor modules with solid light guides and 24 × 24 arrays can be identified when using a partly segmented light guide. The pixel resolution around the edges and corners of the flood map is further improved when TCoG is used for coordinate reconstruction. SUMMARY: We show that the introduction of a partly segmented light guide greatly improves coordinate reconstruction accuracy at the edges of a sensor module. In addition, it is demonstrated that the partly segmented light guides can be used in parallel with other proposed methods designed to fix the "edge effect", including TCoG, to further coordinate reconstruction improve accuracy and crystal flood map quality.

Indexed as

detectorslight guideorgan-targeted PETpartly segmented light guide