Evidence map›Paper›PMID 41305120›Full record

ArticleSensors (Basel, Switzerland)2025

High-Sensitivity Air-Coupled Ultrasonic Transducer Design Based on PMN-PT Bending Vibration Modes.

Junwen Deng, Xingyu Chen, Yuliang Zhu, Xiaobo Wang, Tao Han, Chengtao Luo

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Junwen DengSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.
Xingyu ChenSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.
Yuliang ZhuSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0005-4339-485X
Xiaobo WangSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0009-0007-0795-253X
Tao HanSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.
Chengtao LuoSchool of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0003-1207-2960

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gas pipelines are a critical means of transportation in industrial production. To detect gas pipeline leaks, ultrasonic transducers with specific center frequencies and high sensitivity are required. This paper proposes a novel air-coupled ultrasonic transducer design based on a horn-type matching layer and a bending-mode type of piezoelectric material, specifically tailored for gas leak detection scenarios. The transducer design is optimized by the finite element method, focusing on the basic components of the piezoelectric bimorph, the horn and the supporting tube. First, the influence of various dimensional parameters of the piezoelectric bimorph on the bending vibration mode was analyzed. Then, the effects of the other two components, the horn and the supporting tube, on the piezoelectric bimorph vibration mode were investigated. A parametric scan on the dimensions of these components was conducted to optimize the transducer's output. Finally, ultrasonic transducers using PMN-PT and PZT were fabricated and tested. The results show that the sensitivity of those transducers surpasses that of similar commercial transducers, especially the PMN-PT one with a center frequency of 40 kHz and a peak receiving sensitivity of -51.1 dB. This transducer, benefiting from the high-performance piezoelectric material and the bending vibration mode, proves to be a promising candidate for high-precision leak detection in gas pipelines.

Indexed as

air-coupledbending vibration modesgas leak detectionhigh sensitivityultrasonic transducer

Identifiers

PMID41305120
PMCPMC12656213

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.