Evidence map›Paper›PMID 41305117›Full record

ArticleSensors (Basel, Switzerland)2025

picoSMMS: Development and Validation of a Low-Cost and Open-Source Soil Moisture Monitoring Station.

Veethahavya Kootanoor Sheshadrivasan, Jakub Langhammer, Lena Scheiffele, Jakob Terschlüsen, Till Francke

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Veethahavya Kootanoor SheshadrivasanDepartment of Physical Geography and Geoecology, Faculty of Science, Charles University, 128 00 Prague, Czech Republic.ORCID 0000-0002-2709-2967
Jakub LanghammerDepartment of Physical Geography and Geoecology, Faculty of Science, Charles University, 128 00 Prague, Czech Republic.ORCID 0000-0003-4039-2187
Lena ScheiffeleInstitute of Environmental Science and Geography, University of Potsdam, 14476 Potsdam, Germany.ORCID 0000-0003-3621-680X
Jakob TerschlüsenInstitute of Environmental Science and Geography, University of Potsdam, 14476 Potsdam, Germany.ORCID 0009-0004-1307-9501
Till FranckeInstitute of Environmental Science and Geography, University of Potsdam, 14476 Potsdam, Germany.ORCID 0000-0001-8934-4421

Funding

Czech Science Foundation 22-12837SDeutsche Forschungsgemeinschaft research unit FOR 2694, project number 357874777Grant Agency of Charles University (GAUK) 3300-246623
6 · The paper itself

Abstract

Soil moisture exhibits high spatio-temporal variability that necessitates dense monitoring networks, yet the cost of commercial sensors often limits widespread deployment. Despite the mass production of low-cost capacitive soil moisture sensors driven by IoT applications, significant gaps remain in their robust characterisation and in the availability of open-source, reproducible monitoring systems. This study pursues two primary objectives: (1) to develop an open-source, low-cost, off-grid soil moisture monitoring station (picoSMMS) and (2) to conduct a sensor-unit-specific calibration of a popular low-cost capacitive soil moisture sensor (LCSMS; DFRobot SEN0193) by relating its raw output to bulk static relative dielectric permittivity (ϵs), with the additional aim of transferring technological gains from consumer electronics to hydrological monitoring while fostering community-driven improvements. The picoSMMS was built using readily available consumer electronics and programmed in MicroPython. Laboratory calibration followed standardised protocols using reference media spanning permittivities from 1.0 (air) to approximately 80.0 (water) under non-conducting, non-relaxing conditions at 25 ± 1 °C with temperature-dependency characterisation. Models were developed relating the sensor's output and temperature to ϵs. Within the target permittivity range (2.5-35.5), the LCSMS achieved a mean absolute error of 1.29 ± 1.07, corresponding to an absolute error of 0.02 ± 0.01 in volumetric water content (VWC). Benchmarking revealed that the LCSMS is competitive with the ML2 ThetaProbe, and outperforms the PR2/6 ProfileProbe, but is less accurate than the SMT100. Notably, applying the air-water normalisation procedure to benchmark sensors significantly improved their performance, particularly for the ML2 ThetaProbe and PR2/6 ProfileProbe. A brief field deployment demonstrated the picoSMMS's ability to closely track co-located HydraProbe sensors. Important limitations include the following: inter-sensor variability assessment was limited by the small sensor ensemble (only two units), and with a larger sample size, the LCSMS may exhibit greater variability, potentially resulting in larger prediction errors; the characterisation was conducted under non-saline conditions and may not apply to peat or high-clay soils; the calibration is best suited for the target permittivity range (2.5-35.5) typical of mineral soils; and the brief field deployment was insufficient for long-term validation. Future work should assess inter-sensor variability across larger sensor populations, characterise the LCSMS under varying salinity, and conduct long-term field validation.

Indexed as

capacitive sensorlow-cost sensormonitoring stationopen sourcesoil moisture sensor

Identifiers

PMID41305117
PMCPMC12656263

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.