Evidence map›Paper›PMID 41302766›Full record

ArticleMicromachines2025

3D-Printed Microneedles with Controlled Structures for Drug Delivery Study in an Ex Vivo Model.

Dong Wei, Weixiong Yang, Xiang Song, Fu Liu

Abstract read
In one paragraph

Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dong WeiDepartment of Oncology, Second Hospital of Shanxi Medical University, No. 382 Wuyi Road, Taiyuan 030001, China.
Weixiong YangSchool of Mechanical Engineering & Automation, Beihang University, No. 37 Xueyuan Road, Beijing 100191, China.
Xiang SongDepartment of Oncology, Second Hospital of Shanxi Medical University, No. 382 Wuyi Road, Taiyuan 030001, China.ORCID 0000-0001-9269-1934
Fu LiuSchool of Aerospace Engineering, North University of China, No. 3 Xueyuan Road, Taiyuan 030051, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

MN arrays are highly beneficial for transdermal drug delivery, primarily due to reduced pain and improved compliance. However, complex processing and restricted design freedom limit traditional fabrication. We utilized stereolithography (SLA) 3D printing as a breakthrough method to achieve the one-step production of MN arrays with customized geometries (structure, size, tip angle), enabling tunable release profiles and eliminating cumbersome manufacturing steps. After fabricating conical and grooved MN arrays and validating them in an ex vivo porcine skin model, we confirmed their functionality. Notably, the grooved design provided excellent penetration, requiring only 2.2 N of force for full insertion (at 18.92° tip angle), and demonstrated an enhanced drug loading capacity of 4.8 μg released over 2 h. These results underscore the significant potential of 3D-printed, channel-structured MN arrays as a new generation of high-performance transdermal delivery devices.

Indexed as

3D printingcontrolled structuresdrug deliverymicroneedle arrays

Identifiers

PMID41302766
PMCPMC12654216

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.