Evidence map›Paper›PMID 41299564›Full record

ArticleBMC oral health2025

Accuracy of robotic-assisted implant placement in second molars combined with step drills and manual-automatic switching function: a retrospective study.

Tao Yang, Xiaojian Xing, Wenan Xu, Buling Wu

Abstract read
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tao YangShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Shenzhen, China.
Xiaojian XingShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Shenzhen, China.
Wenan XuShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Shenzhen, China.
Buling WuShenzhen Clinical College of Stomatology, School of Stomatology, Southern Medical University, Shenzhen, China. bulingwu@smu.edu.cn.ORCID http://orcid.org/0000-0002-9678-6962

Funding

Shenzhen Science and Technology Program JCYJ20220530162408020the President Foundation of Shenzhen Stomatology Hospital (Pingshan), Southern Medical University 2022A001the President Foundation of Shenzhen Stomatology Hospital (Pingshan), Southern Medical University 2022C003
6 · The paper itself

Abstract

backgroundNowadays, robotic computer-assisted implant surgery (r-CAIS) has drawn great attention in implant dentistry; however, the clinical application of r-CAIS for limited operating space such as the second molar region, has not been demonstrated. Thus, this study aimed to evaluate the accuracy of r-CAIS in second molars in combination with step drills and manual-automatic mode switching function.

methodsPatients who lost second molars and underwent r-CAIS were enrolled in this study. The positioning marker was installed preoperatively, and a cone-beam computed tomography (CBCT) scan was subsequently performed. The CBCT data were subsequently transferred into the robotic software, and a preoperative surgical plan was generated. After marker registration and calibration, the implant osteotomy was completed by the robotic arm under the control of the surgeons. Owing to the limited operating space in the second molar region, the operation mode of r-CAIS was switched between manual and automatic modes, and step drills were used in combination. Patients underwent postoperative CBCT, and the accuracy was evaluated using the CBCT data between the planned and placed implants.

resultsA total of 16 patients were enrolled in this study, and no adverse events occurred during or after surgery. The mean global coronal, apical and angular deviations were 0.43 ± 0.10 mm (95%CI: 0.38 to 0.49 mm), 0.44 ± 0.10 mm (95%CI: 0.38 to 0.49 mm), and 0.88 ± 0.53°(0.60 to 1.16°), respectively.

conclusionsr-CAIS can achieve high accuracy in the second molar region when combined with step drills and manual-automatic mode switching function. Further prospective studies are needed to validate the effects.

Indexed as

Dental Implantation, EndosseousMolarRobotic Surgical ProceduresSurgery, Computer-AssistedCone-Beam Computed TomographyFemaleHumansMaleRetrospective StudiesAccuracyImplant placement surgeryRobotic-assistedSecond molarStep drills

Identifiers

PMID41299564
PMCPMC12659220

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.