Evidence map›Paper›PMID 41299298›Full record

Observational studyBMC emergency medicine2025

Effectiveness of mechanical and manual cardiopulmonary resuscitation: evaluation with carotid doppler and metabolic parameters.

İsmail Batuhan Vergi, Mustafa Burak Sayhan, Eray Çeliktürk, Satuk Buğra Han Bozatlı

Abstract readObservational Study
In one paragraph

Observational study in BMC emergency medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Guideline
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

İsmail Batuhan VergiDenizli State Hospital, Denizli, Türkiye. batuhanvergi@icloud.com.
Mustafa Burak SayhanDepartment of Emergency Medicine, Trakya University Medicine Faculty, Edirne, Türkiye.
Eray ÇeliktürkDepartment of Emergency Medicine, Trakya University Medicine Faculty, Edirne, Türkiye.
Satuk Buğra Han BozatlıDepartment of Emergency Medicine, Trakya University Medicine Faculty, Edirne, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim was to compare the hemodynamic and metabolic effectiveness of manual chest compressions and a mechanical chest compression device during in-hospital cardiac arrest by monitoring carotid Doppler flow and end-tidal carbon dioxide (ETCO₂) and arterial lactate levels.

methodsIn this single-center, prospective, observational cohort study, 54 adult patients with nontraumatic cardiac arrest in the emergency department were enrolled between December 2023 and February 2024. Chest compressions were delivered manually for the first three 2-minute cycles and mechanically for the subsequent two cycles. The peak-systolic velocity (PSV) and end-diastolic velocity (EDV) of the common carotid artery and the ETCO₂ and lactate levels were recorded at cycles 1, 3 and 5. The primary and secondary outcomes were the return of spontaneous circulation (ROSC) and 24-h survival, respectively. The predictive performance of physiological markers was assessed with receiver operating characteristic (ROC) analysis.

resultsROSC was achieved in 41/54 patients (75.9%), and 22/41 patients (53.7%) were alive at 24 h. The ultrasound acquisition time decreased from 39.9 ± 7.2 s in the first (manual) cycle to 25.7 ± 5.5 s in the fifth (mechanical) cycle (p < 0.01). Compared with manual cardiopulmonary resuscitation (CPR), mechanical compression was associated with greater increases in PSV (Δ₃-₅ = 9.0 ± 3.3 cm s⁻¹ vs. Δ₁-₃ = 2.7 ± 2.9 cm s⁻¹; p < 0.01) and EDV, a greater increase in ETCO₂ (3.5 ± 1.7 mm Hg vs. 1.3 ± 1.6 mm Hg; p < 0.01) and a more pronounced decrease in lactate levels (-0.30 ± 0.34 mmol L⁻¹ vs. -0.10 ± 0.19 mmol L⁻¹; p < 0.01). An ETCO₂ value ≥ 35 mm Hg predicted ROSC with 75.6% sensitivity and 53.9% specificity (AUC = 0.70), whereas a lactate level ≤ 5.3 mmol L⁻¹ predicted ROSC with 76.9% sensitivity and 82.9% specificity (AUC = 0.81). Carotid Doppler velocities showed limited discrimination for ROSC (AUC ≈ 0.56-0.58) and should not be used alone for prognostication.

conclusionCompared with the preceding manual cycles, the mechanical cycles were associated with higher carotid flow velocities and more favorable ETCO₂-lactate trajectories; however, given the fixed sequence and co-interventions, causality cannot be inferred.

Indexed as

Cardiopulmonary ResuscitationCarotid ArteriesHeart ArrestAdultAgedCarbon DioxideEmergency Service, HospitalFemaleHumansLactic AcidMaleMiddle AgedProspective StudiesUltrasonography, DopplerCarbon DioxideLactic AcidCardiopulmonary resuscitationCarotid dopplerEnd-tidal CO2LactateUltrasonography

Identifiers

PMID41299298
PMCPMC12659239

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.