Evidence map›Paper›PMID 41299268›Full record

Trial reportBMC anesthesiology2025

Dural puncture epidural technique with 23-, 25- or 27-gauge pencil point spinal needles versus standard epidural technique for labor analgesia: a randomized trial.

Zheng-Bin Pan, Jie-Feng Chen, Jie-Lan Ding, Zhi-Min Sheng, Hao Lv, Zhong Mei, Wei-Wei Shui, Yiyu Pan

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in BMC anesthesiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zheng-Bin PanDepartment of Anesthesiology, Shaoxing Maternity and Child Health Care Hospital, No. 222 Fenglin East Road, Yuecheng, Shaoxing, Zhejiang, 312000, China.
Jie-Feng ChenDepartment of Anesthesiology, Shaoxing Maternity and Child Health Care Hospital, No. 222 Fenglin East Road, Yuecheng, Shaoxing, Zhejiang, 312000, China.
Jie-Lan DingDepartment of Anesthesiology, Shaoxing Maternity and Child Health Care Hospital, No. 222 Fenglin East Road, Yuecheng, Shaoxing, Zhejiang, 312000, China.
Zhi-Min ShengDepartment of Anesthesiology, Wenling maternal and child healthcare hospital, Taizhou, China.
Hao LvDepartment of Anesthesiology, Shaoxing Shangyu Maternal and Child Health Hospital, Shaoxing, China.
Zhong MeiDepartment of Anesthesiology, Zhejiang Xiaoshan Hospital, Hangzhou, China.
Wei-Wei ShuiDepartment of Anesthesiology, Shaoxing Maternity and Child Health Care Hospital, No. 222 Fenglin East Road, Yuecheng, Shaoxing, Zhejiang, 312000, China.
Yiyu PanDepartment of Anesthesiology, Shaoxing Maternity and Child Health Care Hospital, No. 222 Fenglin East Road, Yuecheng, Shaoxing, Zhejiang, 312000, China. yiyupan0842@163.com.

Funding

Shaoxing Health Technology Program Project 2023SKY050Shaoxing Municipal Science and Technology Project 2024A14011
6 · The paper itself

Abstract

backgroundDural puncture epidural (DPE) improves labor analgesia by reducing numeric rating scale (NRS) score, accelerating onset, and enhancing sacral blockade. Although larger-gauge needles may potentiate local anesthetic diffusion and improve analgesic quality, current clinical practice favors smaller-gauge needles (25-gauge to 27-gauge) to mitigate post-dural puncture headache (PDPH) risks. This randomized trial specifically evaluates the differential impacts of 23-gauge, 25-gauge, and 27-gauge needles on both analgesic efficacy and procedure-related complications.

methodsIn this randomized trial, 200 parturients requesting labor analgesia received DPE (23-gauge, 25-gauge, 27-gauge subgroups) or standard epidural (EP), followed by programmed intermittent epidural boluses (PIEB) of 12 mL with ropivacaine 0.08% and sufentanil 0.33 µg/mL every 50 min. Primary outcome was NRS score 10 min after the initial epidural bolus; secondary outcomes included time to NRS score ≤ 1, block characteristics at 20 min, number of top-up boluses, Apgar scores, and adverse events.

resultsAmong 198 analyzed participants, all DPE groups exhibited lower 10-minute NRS scores versus EP groups (P < 0.001). The 23-gauge and 25-gauge subgroups had lower NRS scores than 27-gauge (P < 0.05), with no difference between 23-gauge and 25-gauge (P > 0.05). The 23-gauge group achieved NRS score ≤ 1 fastest (P < 0.001). DPE groups demonstrated higher bilateral sacral (S2) blockade rates versus EP groups (P < 0.001), with no inter-subgroup differences. No significant difference were observed in procedure duration, top-up requirements, catheter adjustments/replacement, complications (PDPH, hypotension, nausea), or neonatal Apgar scores at 1 and 5 min.

conclusionCompared to conventional epidural analgesia, the combined application of DPE and PIEB techniques demonstrated superior quality. The utilization of 25-gauge pencil-point spinal needles achieves the optimal balance between analgesic efficacy and safety, while the 23-gauge needle may be suitable for specific scenarios requiring rapid onset of action.

Indexed as

Analgesia, EpiduralAnalgesia, ObstetricalNeedlesSpinal PunctureAdultAnesthetics, LocalFemaleHumansPost-Dural Puncture HeadachePregnancyRopivacaineSufentanilYoung AdultAnesthetics, LocalRopivacaineSufentanilDural puncture epiduralLabor analgesiaRopivacaineVisual analog scale

Identifiers

PMID41299268
PMCPMC12659314

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.