Evidence map›Paper›PMID 41296009›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2025

Incidence of cough reflex and vagal response among various pulsed field ablation systems: a multicenter registry study.

Iwanari Kawamura, Shinsuke Miyazaki, Junichi Nitta, Osamu Inaba, Atsushi Takahashi, Shu Yamashita, Yasutoshi Nagata, Shinsuke Iwai, Yasuteru Yamauchi, Yoshihide Takahashi and 2 more

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Iwanari KawamuraDepartment of Cardiovascular Medicine, Institute of Science Tokyo, Yushima 1-5-45, Bunkyo-Ku, Tokyo, 113-8510, Japan.
Shinsuke MiyazakiDepartment of Cardiovascular Medicine, Institute of Science Tokyo, Yushima 1-5-45, Bunkyo-Ku, Tokyo, 113-8510, Japan. mmshinsuke@gmail.com.ORCID http://orcid.org/0000-0002-0230-0934
Junichi NittaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Osamu InabaDepartment of Cardiology, Japanese Red Cross Saitama Hospital, Saitama, Japan.
Atsushi TakahashiDepartment of Cardiology, Yokosuka Kyosai Hospital, Kanagawa, Japan.
Shu YamashitaDepartment of Cardiology, NHO Disaster Medical Center, Tokyo, Japan.
Yasutoshi NagataDepartment of Cardiology, Japanese Red Cross Musashino Hospital, Tokyo, Japan.
Shinsuke IwaiDepartment of Cardiology, Hiratsuka Kyosai Hospital, Kanagawa, Japan.
Yasuteru YamauchiDepartment of Cardiology, Japanese Red Cross Yokohama City Bay Hospital, Kanagawa, Japan.
Yoshihide TakahashiDepartment of Cardiovascular Medicine, Shin-Yurigaoka General Hospital, Kanagawa, Japan.
Hitoshi HachiyaCardiovascular Center, Tsuchiura Kyodo Hospital, Ibaraki, Japan.
Tetsuo SasanoDepartment of Cardiovascular Medicine, Institute of Science Tokyo, Yushima 1-5-45, Bunkyo-Ku, Tokyo, 113-8510, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimsCough reflex and vagal reflex-induced bradycardia are important to predict and prevent prior to PFA to ensure procedural safety and efficacy. However, no studies have yet investigated differences in their incidence among the various PFA systems. We aimed to evaluate the incidence, predictors, and system-specific differences of cough reflex and vagal response during PFA in a large multicenter cohort.

methodsData from 1715 patients undergoing PFA using either PulseSelect, Farapulse, or Varipulse systems at 13 centers were analyzed. Cough reflex was defined as any episode requiring procedure interruption or physical restraint, while a vagal response was defined as sinus arrest or atrioventricular block lasting ≥ 5 s.

resultsPulmonary vein isolation was achieved in all patients except for one case. Complications were rare and did not differ significantly among the PFA systems. Cough reflex occurred in 49.3% of patients, most frequently in the left superior pulmonary vein. Compared with Farapulse, the risk of cough reflex was higher with PulseSelect (odds ratio [OR] 1.648, 95% confidence interval [CI] 1.321-2.057) and Varipulse (OR 1.645, 95% CI 1.019-2.657). Patient-related factors such as male sex, asthma, heart failure, and hypertension increased the risk, whereas general anesthesia significantly reduced it (OR 0.236, 95% CI 0.174-0.318). Vagal response occurred in 15.2% of patients, with no significant differences among the PFA systems, and the sequence of pulmonary vein isolation did not affect its occurrence. Prophylactic atropine reduced the risk of vagal response.

conclusionCough reflex may vary across PFA systems, while vagal response may remain consistent.

Indexed as

AnticholinergicAtropineComplicationCough reflexElectroporationVagal response

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.