Evidence map›Paper›PMID 41295973›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2025

Correction of foreshortening and tube potential bias for improved quantitative angiographic assessment of intracranial aneurysms.

Ahmad Rahmatpour, Parisa Naghdi, James Jf Crouch, Kyle A Williams, Parmita Mondal, Michael H Udin, Swetadri Vasan Setlur Nagesh, Adnan H Siddiqui, Elad L Levy, Jason M Davies and 1 more

Expression of concernAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It carries an expression of concern. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors.

Ahmad RahmatpourDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0009-0008-5864-3582
Parisa NaghdiDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0009-0000-4057-6766
James Jf CrouchDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0009-0001-8107-6108
Kyle A WilliamsDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0003-2642-8630
Parmita MondalDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0009-0002-3134-6103
Michael H UdinCanon Stroke and Vascular Research Center, Buffalo, NY, USA.ORCID 0009-0006-9465-3919
Swetadri Vasan Setlur NageshCanon Stroke and Vascular Research Center, Buffalo, NY, USA.ORCID 0000-0001-6466-5368
Adnan H SiddiquiDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-9519-0059
Elad L LevyDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-6208-3724
Jason M DaviesDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0002-5225-3072
Ciprian N IonitaDepartment of Biomedical Engineering, University at Buffalo, Buffalo, NY, USA.ORCID 0000-0001-7049-0592

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BackgroundQuantitative angiography (QA) can extract hemodynamic information during neurointerventional procedures by leveraging contrast flow biomarkers. However, clinical adoption of two-dimensional (2D) QA remains limited compared with three-dimensional (3D) methods such as CT perfusion due to view-dependent biases when projecting 3D flow onto 2D images. Variations in tube potential (kVp) further modulate iodine attenuation, introducing intensity inconsistencies that confound QA measurements. This study evaluates a path-length correction (PLC) method designed to reduce orientation- and acquisition-related biases in 2D digital subtraction angiography (DSA).Materials and methodsThree cerebrovascular cases containing rotational and 2D DSAs were retrospectively analyzed. 3D volumes were reconstructed using cone-beam algorithms, and synthesized projections were spatially aligned with 2D DSA images using affine and non-linear transformations. Frame intensities were normalized for kVp using an iodine mass attenuation lookup. Path-length maps derived from aligned 3D volumes were then used to normalize DSA intensities, generating PLC images. QA parameters-peak height and area under the curve-were computed from pixel-wise time-density curves (TDCs) at matched regions of interest within aneurysm and parent vessels. PLC performance was evaluated by comparing root mean squared errors (RMSEs) between frontal and lateral TDCs and discrepancies in QA parameters before and after correction.ResultsAcross three cases, PLC improved cross-view consistency by reducing TDC RMSE from 0.23 ± 0.04 to 0.14 ± 0.04, peak height RMSE from of 0.42 ± 0.16 to 0.15 ± 0.11, and area under the curve RMSE from 0.43 ± 0.13 to 0.14 ± 0.13.ConclusionsThe PLC method reduces foreshortening bias in 2D DSA and improves consistency of QA metrics, enhancing reliability in cerebrovascular assessment and treatment evaluation using clinical DSA.

Indexed as

aneurysmdigital subtracting angiographyforeshortening biaspath length correctionQuantitative angiography

Identifiers

PMID41295973
PMCPMC12657199

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.