Evaluating the Performance of Hyperspectral Imaging Endoscopes: Mitigating Parameters Affecting Spectral Accuracy.

Siavash Mazdeyasna, Mohammed Shahriar Arefin, Andrew Fales, Silas J Leavesley, T Joshua Pfefer, Quanzeng Wang

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Siavash MazdeyasnaCenter for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA.ORCID 0000-0001-5683-9866
Mohammed Shahriar ArefinCenter for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA.
Andrew FalesCenter for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA.ORCID 0000-0001-7232-8636
Silas J LeavesleyChemical and Biomolecular Engineering, University of South Alabama, Mobile, AL 36688, USA.ORCID 0000-0002-2684-9534
T Joshua PfeferCenter for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA.
Quanzeng WangCenter for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA.ORCID 0000-0002-0557-7058

Funding

United States Food and Drug Administration 2023DBP1099
6 · The paper itself

Abstract

Hyperspectral imaging (HSI) is increasingly used in studies for medical applications as it provides both structural and functional information of biological tissue, enhancing diagnostic accuracy and clinical decision-making. Recently, HSI cameras (HSICs) have been integrated with medical endoscopes (HSIEs), capturing hypercube data beyond conventional white light imaging endoscopes. However, there are currently no cleared or approved HSIEs by the U.S. Food and Drug Administration (FDA). HSI accuracy depends on technologies and experimental parameters, which must be assessed for reliability. Importantly, the reflectance spectrum of a target can vary across different cameras and under different environmental or operational conditions. Thus, before reliable clinical translation can be achieved, a fundamental question must be addressed: can the same target yield consistent spectral measurements across different HSI systems and under varying acquisition conditions? This study investigates the impact of eight parameters-ambient light, exposure time, camera warm-up time, spatial and temporal averaging, camera focus, working distance, illumination angle, and target angle-on spectral measurements using two HSI techniques: interferometer-based spectral scanning and snapshot. Controlled experiments were conducted to evaluate how each parameter affects spectral accuracy and whether normalization can mitigate these effects. Our findings reveal that several parameters significantly influence spectral measurements, with some having a more pronounced impact. While normalization reduced variations for most parameters, it was less effective at mitigating errors caused by ambient light and camera warm-up time. Additionally, normalization did not eliminate spectral noise resulting from low exposure time, small region of interest, or a spectrally non-uniform light source. From these results, we propose practical considerations for optimizing HSI system performance. Implementing these measures can minimize variations in reflectance spectra of identical targets captured by different cameras and under diverse conditions, thereby supporting the reliable translation of HSI techniques to clinical applications.

Indexed as

EndoscopesHyperspectral ImagingHumansambient lightcamera focuscamera warm-up timeexposure timehyperspectral endoscopeillumination angleinterferometer-based spectral scanningmedical hyperspectral imagingnormalizationoptimizationreflectance spectrumsnapshotspatial and temporal averagingspectral accuracyspectral noisetarget angleworking distance