Volumetric ultrasound and photoacoustic imaging of inflammatory arthritis in human finger joints via robotic arm powered arc scans.

Kyoungmo Koo, Xiaorui Peng, Guangshen Ma, Nada Abdulaziz, David Mills, Aaron Dentinger, Girish Gandikota, Mark Draelos, Xueding Wang

Abstract read
In one paragraph

Article in Biomedical optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kyoungmo KooDepartment of Robotics, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA.
Xiaorui PengDepartment of Biomedical Engineering, University of Michigan, 1150 Medical Center Dr, Ann Arbor, MI 48109, USA.ORCID https://orcid.org/0000-0001-5756-7591
Guangshen MaDepartment of Robotics, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA.ORCID https://orcid.org/0000-0003-3468-9523
Nada AbdulazizDivision of Rheumatology, Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA.
David MillsGE HealthCare Technology & Innovation Center, Niskayuna, NY, USA.
Aaron DentingerGE HealthCare Technology & Innovation Center, Niskayuna, NY, USA.
Girish GandikotaDepartment of Radiology, University of North Carolina, School of Medicine, NC, USA.
Mark DraelosDepartment of Robotics, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA.ORCID https://orcid.org/0000-0002-5051-0880
Xueding WangDepartment of Biomedical Engineering, University of Michigan, 1150 Medical Center Dr, Ann Arbor, MI 48109, USA.

Funding

Medical Scientist Training Program Training GrantT32GM145449 · NIGMS · DUKE UNIVERSITY · PI Christopher D Kontos · 2022 to 2026
$6.6M
NIGMS NIH HHS T32 GM145449
6 · The paper itself

Abstract

Ultrasound (US) imaging is a standard clinical tool for assessment of soft tissue inflammation, particularly for imaging the peripheral joints of the hands and feet, which are usually the first to be affected by rheumatoid arthritis. Robotic US has recently gained attention as a means of delivering repeatable and operator-independent imaging. Previously developed robotic US for 3D volumetric imaging of human finger joints relies on the linear scan of the target joint to collect a series of 2D B-mode US images. Although effective in many contexts and simple in control and image reconstruction, the linear scan is suboptimal for imaging cylindrical tissue structures such as human fingers, often exhibiting degraded image quality in peripheral regions due to poor angular alignment with the tissue surface. To address this limitation, we developed a robotic US system incorporating an arc-shaped scanning trajectory designed to maintain a consistently perpendicular orientation to the curved surface of the finger throughout the scan. In an experiment on a spherical phantom, arc scan yielded improved boundary sharpness and image contrast compared to linear scan. In a clinical study involving both a healthy volunteer and an arthritis patient, the arc scan produced better B-mode US image quality in imaging finger joints compared to the linear scan, as reflected in more consistent representations of phalangeal and soft tissue structures along different radial directions. Functional Doppler US and photoacoustic (PA) imaging of finger joints were also conducted. Arc scan and linear scan achieved comparable detection of vascular signals. These findings demonstrate that arc scan facilitated by the robotic arm can achieve improved B-mode US imaging of tissue anatomy in human finger joints while preserving the functional imaging capability of Doppler US and PA imaging.