Evaluation of the accuracy, precision, and agreement of a glucometer compared to the standard laboratory test in diabetic and non-diabetic patients.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Technology in Diabetes: A Year in Review.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2026Review
- A High-Precision Screen-Printed Glucose Sensor with In Situ Impedance-Based HCT Correction and Temperature Compensation.Biosensors · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Blood glucose monitoring is vital for diabetes management, with nurses playing a key role in glycemic monitoring and patient education. Despite their widespread use, the precision, accuracy and agreement of fingerprick glucometers with laboratory standards remain a significant concern. Discrepancies arise from multiple sources such as differences in sample type (whole blood vs. serum) and enzymatic technologies, potentially leading to clinical errors. Current international standards like ISO 15,197 have been insufficient in ensuring reliable device performance. Therefore, we need more rigorous benchmarking standards to assess their safety and reliability. This study aimed to evaluate the analytical and clinical accuracy, precision, and agreement of the glucosureSTAR point-of-care (POCT) glucometer against the standard laboratory method in diabetic and non-diabetic patients, following the ISO 15197:2013 standards. A cross-sectional study was conducted on 589 participants (136 diabetic and 453 non-diabetic). Paired blood glucose measurements were taken using the glucosureSTAR glucometer (glucose oxidase method) and a Roche Hitachi 917 laboratory analyzer. Analytical accuracy was assessed against ISO 15197:2013 criteria (± 15 mg/dL for values < 100 mg/dL, ± 15% for values ≥ 100 mg/dL). Clinical accuracy was evaluated using Parkes and Clarke Error Grid Analyses. Agreement was statistically analyzed using Bland-Altman plots, Passing-Bablok regression, and the Concordance Correlation Coefficient (CCC). Precision was tested via the coefficient of variation from 20 repeated measurements on three samples. Diagnostic performance was assessed using ROC curve analysis. The analytical accuracy of the glucometer marginally met the ISO 15197:2013 criteria (95.1% of results within ± 15 mg/dL or ± 15%). While clinical accuracy was acceptable (100% of points in Parkes error grid zones A/B), significant systematic error was observed. The device consistently underestimated blood glucose (mean bias: -3.3 mg/dL; 95% LoA: -38.7 to 32.1 mg/dL) with poor absolute agreement (CCC = 0.886). Precision failed ISO requirements at medium and high concentrations. ROC analysis revealed suboptimal diagnostic performance for detecting diabetes (AUC = 0.816; sensitivity = 62.18%, specificity = 93.26% at > 124 mg/dL cut-off). In conclusion, while the glucosureSTAR glucometer demonstrated acceptable clinical risk assessment with 100% of readings in clinically acceptable error grid zones, it showed significant limitations in analytical performance. The device exhibited systematic underestimation, wide variability, and failed to meet precision requirements at medium and high glucose concentrations. With 95.1% of the data points falling within the acceptable range by ISO15197:2013, and suboptimal diagnostic accuracy (sensitivity: 62.18%), this device should not be considered suitable for diagnostic purposes or therapy adjustment. It may be used with caution for trend monitoring in known diabetic patients where rapid results are prioritized over absolute accuracy but cannot replace standard laboratory methods when precise measurement is critical.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.