Evidence map›Paper›PMID 41290537›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026

Curved Bistable Origami-Inspired Flexible Transcatheter Mitral Valve Clamping.

Siyu Gao, Fan Jiang, Xiuting Sun, Peng Qi, Jian Xu

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Curved Bistable Origami-Inspired Flexible Transcatheter Mitral Valve Clamping.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Siyu GaoSchool of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, 201800, China.
Fan JiangSchool of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, 201800, China.
Xiuting SunSchool of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, 201800, China.ORCID https://orcid.org/0000-0002-0515-0636
Peng QiDepartment of Control Science and Engineering, College of Electronics and Information Engineering, Tongji University, Shanghai, 200082, China.
Jian XuSchool of Aerospace Engineering and Applied Mechanics, Tongji University, Shanghai, 201800, China.

Funding

Fundamental Research Funds for Central Universities 2023YFB4705200National Key Research and Development Program of China 2023YFB4705200National Natural Science Foundation of China 12372022National Natural Science Foundation of China 12372043National Natural Science Foundation of China 124B2030National Natural Science Foundation of China U2441202
6 · The paper itself

Abstract

Curved origami exhibits remarkable potential for minimally invasive medical applications owing to its unique geometric programmability and mechanical tunability. Building on this concept, a curved origami with bistable mechanical behavior is proposed, specifically engineered for transcatheter mitral valve clamping surgery. Benefiting from its bistable characteristics, the curved origami structure enables three key functions: it remains compactly folded during catheter delivery, self-deploys rapidly and precisely at the target site, and maintains a stable, fully expanded configuration during device retrieval. The equivalent stiffness of the curved origami mechanism is tuned through geometric nonlinearity, ensuring that its critical transition load closely simulates the catheter-based delivery conditions. Theoretical analysis and experimental validation confirm that bistability is effectively preserved, while parameters such as initial curvature, thickness, crease curvature, and segment length can be adjusted to precisely tailor the radial support stiffness, meeting the mechanical requirements for resisting mitral valve contraction forces. In vitro experiments further verify the dilator's exceptional stability and fully reliable deployment within a simulated mitral valve environment. This work advances the engineering application of curved origami mechanics in minimally invasive medical treatments, offering both theoretical insights and promising potential for clinical translation.

Indexed as

Cardiac CatheterizationMitral ValveHeart Valve ProsthesisHumansbistable curved origamicurvature of spaceinterventional medical devicestiffness designtranscatheter mitral valve clamping

Identifiers

PMID41290537
PMCPMC12884735

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked