ArticleMedical physics2025
Adaptation of a small animal radiation research platform for pre-clinical microbeam irradiations.
Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Adaptation of a small animal radiation research platform for pre-clinical microbeam irradiations.Medical physics · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundMicrobeam radiotherapy (MRT) was introduced as a method to widen the therapeutic window compared to standard radiotherapy treatments. Studies have shown the normal tissue sparing effects of MRT, whilst maintaining the tumor control of standard broad beam radiotherapy. PURPOSE: To create and test a microbeam (MB) delivery system compatible with a small animal radiation research platform (SARRP, Xstrahl), which would allow the machine to be easily adapted to deliver MB irradiations without making any permanent changes to the system.
methodsA MB collimator was designed, that fits in with the existing SARRP infrastructure and can easily be removed to revert the machine back to a normal broad beam delivery system. A translatable mousebed was developed to reduce the source-to-surface distance (SSD) for MB delivery, allowing the target position to be moved between imaging and treatment. Gafchromic film was used to test the accuracy of the positioning, and to determine the dose rates achievable in a solid water phantom.
resultsAt 1 mm depth in solid water, a peak-to-valley dose ratio (PVDR) of 46 was achieved when the target was placed directly under the collimator, whilst a PVDR of 29 was reached when a 10.5 mm air gap was introduced between the collimator and target. Integral dose rates at 1 mm depth for these setups were 0.93 ± 0.04 and 0.94 ± 0.01 Gy/min, respectively. Conversion between broad beam and microbeam setup was found to take less than 5 min.
conclusionsOur adaptations enable any SARRP machine to be converted into a MB delivery system, with feasibility studies confirming MB delivery in a solid water phantom. The system is now routinely used to deliver MBs for in vivo studies.