Evidence map›Paper›PMID 41289322›Full record

ArticlePloS one2025

SVNC-Net: An optimized U-Net variant with 2D convolutions for lightweight 3D spleen segmentation.

Mehmet Zahid Genc, Yaser Dalveren, Ali Kara, Mohammad Derawi, Jan Kubicek, Marek Penhaker

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mehmet Zahid GencDepartment of Electrical and Electronics Engineering, Gazi University, Ankara, Turkey.ORCID https://orcid.org/0009-0007-3696-8880
Yaser DalverenDepartment of Electrical and Electronics Engineering, Izmir Bakircay University, Izmir, Turkey.ORCID https://orcid.org/0000-0002-9459-0042
Ali KaraDepartment of Electrical and Electronics Engineering, Gazi University, Ankara, Turkey.ORCID https://orcid.org/0000-0002-9739-7619
Mohammad DerawiDepartment of Cybernetics and Biomedical Engineering, VSB - Technical University of Ostrava, Ostrava, Czechia.
Jan KubicekDepartment of Cybernetics and Biomedical Engineering, VSB - Technical University of Ostrava, Ostrava, Czechia.ORCID https://orcid.org/0000-0003-0185-422X
Marek PenhakerDepartment of Cybernetics and Biomedical Engineering, VSB - Technical University of Ostrava, Ostrava, Czechia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate measurement of spleen volume is essential for the diagnosis of splenomegaly. While Computed Tomography (CT) is among the most reliable imaging modalities for this task, manual segmentation of the spleen is labor-intensive and impractical for routine clinical workflows. Automatic segmentation methods provide a more viable alternative for clinical deployment. In recent years, 3D Convolutional Neural Network (CNN) models have been widely used for this purpose due to their high segmentation accuracy. However, their computational and memory demands make them less suitable for real-time applications on edge devices with limited processing capabilities. To address these limitations, we introduce SVNC-Net (Spleen Volume and Neighborhood Convolutional Network) for efficient 3D spleen segmentation from CT scans. Rather than developing an entirely new architecture from scratch, SVNC-Net builds upon the U-Net framework with targeted architectural optimizations for efficiency. In SVNC-Net, each CT slice is processed independently using 2D convolutions. In its architecture, depthwise separable convolution is used to significantly reduce computational complexity and memory usage. To evaluate its performance and efficiency, a comparative analysis was conducted against well-known CNN-based models, including UPerNet, EMANet, CCNet, SegNet, and ShuffleNet. This evaluation was performed on two publicly available datasets used together for the first time in the literature. The promising results achieved from the comparative analysis verified that SVNC-Net is highly suitable for real-time applications and resource-constrained environments. Additionally, we explore post-training compression techniques such as pruning and quantization, which further enhance the model's compactness and inference speed. These findings contribute to the ongoing efforts to develop efficient 2D deep learning models for 3D organ segmentation, particularly in resource-constrained clinical scenarios.

Indexed as

Image Processing, Computer-AssistedImaging, Three-DimensionalNeural Networks, ComputerSpleenSplenomegalyTomography, X-Ray ComputedAlgorithmsDeep LearningHumans

Identifiers

PMID41289322
PMCPMC12646407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.