Evidence map›Paper›PMID 41287055›Full record

SynthesisHead & face medicine2025

Fixture design effects on posterior dental implant stability using finite element analysis (FEA): a systematic review.

Kriswanto Kriswanto, Jamari Jamari, Rachael Andika, Athanasius Priharyoto Bayuseno, Abdulfatah Abdu Yusuf, Muhammad Imam Ammarullah

Abstract readSystematic ReviewReview
In one paragraph

Synthesis in Head & face medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kriswanto KriswantoDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang, Central Java, 50275, Indonesia. kriswanto@mail.unnes.ac.id.ORCID http://orcid.org/0009-0004-2845-700X
Jamari JamariDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang, Central Java, 50275, Indonesia.ORCID http://orcid.org/0000-0002-6172-2635
Rachael AndikaDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Negeri Semarang, Semarang, Central Java, 50229, Indonesia.ORCID http://orcid.org/0009-0008-0331-0190
Athanasius Priharyoto BayusenoDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang, Central Java, 50275, Indonesia.ORCID http://orcid.org/0000-0002-0882-4480
Abdulfatah Abdu YusufDepartment of Mechanical Engineering, College of Engineering, University of Liberia, Monrovia, Montserrado, 1000, Liberia.ORCID http://orcid.org/0000-0002-8054-9022
Muhammad Imam AmmarullahDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang, Central Java, 50275, Indonesia. imamammarullah@gmail.com.ORCID http://orcid.org/0000-0002-8845-7202

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Tooth loss is prevalent in the posterior region, and dental implants require optimized fixture design to ensure biomechanical stability, which is often the approach using finite element analysis (FEA). This systematic review, using Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines in its writing, aimed to assess the influence of fixture design on posterior implant biomechanical stability, such as stress and strain, by FEA analysis. The study search used PubMed, ScienceDirect, MDPI, SpringerLink, and OpenAire databases to find studies that analyzed fixture level, body shape, thread characteristics, diameter, length, and neck model, covering studies published between 2020 and 12 January 2025. Data from 39 of the 3,562 studies were synthesized narratively, guided by SWiM, and grouped by design parameters, with bias assessed using ROBFEAD. Tissue-level fixtures outperformed bone-level fixtures in reducing cortical bone stress and improving fatigue resistance, while the tapered body shape increased stress distribution in low-density bone (D4). Square threads minimize micro stress and movement, and larger diameters and lengths increase stability, although excessive dimensions increase cortical stress. The micro-thread neck design reduces bone resorption. The high risk of bias resulting from the lack of mechanical validation, isotropic assumptions, and static loading conditions requires attention when interpreting research findings. Clinical or experimental validation is required. Future studies should standardize thread reporting, use computed tomography (CT)-based modeling, and simulate dynamic loading for patient-specific designs.

Indexed as

Dental ImplantsDental Prosthesis DesignFinite Element AnalysisBiomechanical PhenomenaHumansDental ImplantsDental implantFinite element analysis (FEA)Fixture designPatientPosteriorStability

Identifiers

PMID41287055
PMCPMC12777410

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.