Evidence map›Paper›PMID 41285718›Full record

ArticleMicrosystems & nanoengineering2025

Metalens for passive generation of a droplet Bessel beam.

Yongjae Jo, Hanjun Cho, Jungah Kim, Yangkyu Kim, Saewoon Shin, Jong-Chan Park, Inki Kim

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yongjae Jo *Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea.ORCID http://orcid.org/0000-0001-6585-0012
Hanjun Cho *Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea.
Jungah Kim *Department of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea.
Yangkyu Kim *Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Saewoon ShinDepartment of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea.
Jong-Chan ParkDepartment of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea.
Inki KimDepartment of Biophysics, Institute of Quantum Biophysics, Sungkyunkwan University, Suwon, Republic of Korea. inki.kim@skku.edu.ORCID http://orcid.org/0000-0001-8686-6670

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Extending the depth of field (DOF) is essential for large-volume imaging in biological research, particularly in thick tissue environments. Bessel beams and their variants are widely used due to their simplicity and have been successfully applied to in vivo imaging. A recent advancement demonstrated the application of droplet Bessel beams (DBBs) for multi-photon microscopy, enabling functional imaging in live mouse brains. However, DBB generation inevitably requires active phase switching devices such as spatial light modulators, which reduce imaging speed and increase system complexity. This study introduces a droplet Bessel beam metalens (DBBM) that passively generates DBBs without phase switching by employing rectangular meta-atoms for orthogonal polarization modulation and X-shaped meta-atoms for amplitude control. Optical simulations identify optimal DBBM parameters that maximize the point spread function (PSF) aspect ratio while minimizing energy leakage into side lobes. Furthermore, the fabricated DBBM produces PSFs consistent with simulations. Imaging simulations based on three-dimensional confocal images of expansion microscopy-treated organoids demonstrated that the DBBM maintains superior performance even in the presence of aberrations. These findings establish the DBBM as a compact and passive solution for extended DOF imaging without the need for beam-shaping devices. Metalens technology is anticipated to have broad applications in real-time volumetric bioimaging and enable simplified optical system designs.

Identifiers

PMID41285718
PMCPMC12644905

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.