Evidence map›Paper›PMID 41284121›Full record

ArticleAnnals of biomedical engineering2026

A Miniature A-Mode Ultrasound System for Noninvasive Bone Surface Point Cloud Acquisition.

Tianya Xu, Chuanba Liu, Jiayang Mu, Pengbo Wang, WenJuan Ma, Xiqi Jian, Jiumin Yang, Yanqiu Zhang

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tianya Xu *School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China.
Chuanba Liu *Key Laboratory of Mechanism Theory and Equipment Design of Ministry of Education, Tianjin University, Tianjin, 300354, China.
Jiayang MuSchool of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China.
Pengbo WangSchool of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China.
WenJuan MaDepartment of Breast Imaging, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Key Laboratory of Breast Cancer Prevention and Therapy, Tianjin's Clinical Research Center for Cancer, Tianjin Medical University, Ministry of Education, Tianjin, China.
Xiqi JianSchool of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China.
Jiumin YangSchool of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China. jiumin_yang@126.com.
Yanqiu ZhangSchool of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin, 300070, China. tmu_zyq@126.com.

Funding

National Natural Science Foundation of China 82272125Natural Science Foundation of Tianjin Municipality 24JCQNJC01360
6 · The paper itself

Abstract

purposeBone surface registration in current computer-assisted surgical navigation primarily relies on the manual selection of anatomical landmarks and invasive bone surface sampling using mechanical probes. This approach is traumatic, highly dependent on operator expertise, and difficult to automate. Although ultrasound-based registration methods have been explored and demonstrated certain application potential, most existing techniques still rely on manual feature extraction. Moreover, their accuracy is generally limited by the structural and geometric constraints of the probes. To address these limitations, we propose and develop a real-time, noninvasive bone surface depth acquisition system based on A-mode ultrasound, aiming to replace traditional mechanical probing and provide a high-precision, automated, and noninvasive alternative for bone surface registration.

methodsWe optimized the probe geometry using finite-difference time-domain simulations and fabricated a four-element A-mode probe with integrated control and data acquisition systems. An automatic bone-echo detection algorithm based on Gaussian filtering and Hilbert transform was developed. System performance was validated through simulations and benchtop experiments on 3D-printed tibia and spine phantoms.

resultsSimulation and experimental results demonstrate the system achieves millimeter-level bone surface sampling accuracy within a 40 mm depth range, with multiple measurement errors below 1 mm. In registration tests using tibia and spine models, the system achieved average registration errors of 1.426 ± 0.300 mm and 1.262 ± 0.283 mm, respectively.

conclusionThis study proposes and builds an A-mode ultrasound system that, through optimization of a miniature probe and development of an automatic bone echo recognition algorithm, establishes a novel and potentially clinically valuable approach for achieving millimeter-level accuracy in automated, noninvasive registration.

Indexed as

SpineTibiaAlgorithmsHumansPhantoms, ImagingUltrasonographyBone echo recognition algorithmFinite-difference time-domain simulationMiniature A-mode ultrasound systemNon-invasive bone registration

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.