ArticleJournal of radiation research2026

Impact of off-center diagonal profile depth pairing on gamma pass rates in portal dosimetry.

Yuya Suzuki, Atsushi Yamashita, Yoshiaki Okada, Takuya Ochiai, Kouyou Ishida, Kenji Ota, Toshio Ohashi

Abstract read
In one paragraph

Article in Journal of radiation research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuya SuzukiDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.ORCID 0009-0009-9691-5267
Atsushi YamashitaDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.
Yoshiaki OkadaDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.
Takuya OchiaiDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.
Kouyou IshidaDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.
Kenji OtaDepartment of Radiological Technology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.
Toshio OhashiDepartment of Radiation Oncology, Tokyo Saiseikai Central Hospital, 1-4-17 Mita, Minato-ku, Tokyo 108-0073, Japan.ORCID 0000-0002-2011-3016

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study evaluated the impact of off-center diagonal (OCD) profile depth pairing between the treatment planning system (TPS) and the electronic portal imaging device (EPID) on gamma pass rates in portal dosimetry. In clinical workflows, OCD profiles are used in the TPS to generate predicted images via the portal dosimetry image prediction (PDIP) algorithm and in the EPID system to correct measured fluence. The consistency of these settings may influence verification accuracy. Portal images were acquired using a TrueBeam linear accelerator with an aS1200 EPID for four photon energies: 6X, 10X, 6 flattening filter-free (FFF) and 10FFF. Five OCD profiles (reference depth, 5, 10, 20 and 30 cm) were configured in both the PDIP model and EPID system. For each energy, a total of 175 plan-measurement combinations were evaluated, derived from five PDIP OCD depths combined with five EPID OCD depths across seven field sizes. Field sizes ranged from 5 × 5 to 30 × 30 cm2. Gamma analysis used 3%/3 mm criteria with a 10% dose threshold. A two-way analysis of variance assessed the effects of TPS and EPID OCD depths and their interaction. For 6X and 10X beams, pass rates varied with configuration, showing better agreement when depths were matched or EPID was deeper. In contrast, 6FFF and 10FFF beams maintained high pass rates with minimal variation. These findings indicate that OCD depth pairing influences portal dosimetry performance, particularly for flattened beams, underscoring the importance of depth-aware configuration in QA protocols.

Indexed as

Gamma RaysRadiometryRadiotherapy Planning, Computer-AssistedAlgorithmsHumansParticle AcceleratorsRadiotherapy DosageEPIDfluenceoff-center diagonal profilepatient-specific QAportal dosimetry

Identifiers

PMID41283810
PMCPMC12856035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.