Evidence map›Paper›PMID 41283760›Full record

Trial reportJournal of cataract and refractive surgery2026

Randomized comparative multicenter study assessing two dispersive viscosurgical devices for cataract surgery.

Ekkehard Fabian, Andrea Janeková, Pablo de Arriba Palomero, Pedro Tañá-Rivero, Daniel Böhringer, Florian T A Kretz, Jiří Pašta, Rosario Touriño-Peralba

Abstract readMulticenter StudyRandomized Controlled TrialComparative Study
In one paragraph

Trial report in Journal of cataract and refractive surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ekkehard FabianFrom the AugenCentrum - Augenklinik Rosenheim, Rosenheim, Germany (Fabian); Eye Centre Prague, Prague, Czech republic (Janeková); Faculty of Medicine, Charles University, Hradec Kralove, Czech Republic (Janeková); Hospital Universitario Ramón y Cajal, Madrid, Spain (de Arriba Palomero); Oftalvist Alicante, Alicante, Spain (Tañá-Rivero); Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany (Böhringer); Precise Vision Augenärzte - Augentagesklinik Rheine, Rheine, Germany (Kretz); Premium Clinic Teplice, Teplice, Czech Republic (Pašta); Eye Centre, Prague, Czech Republic (Pašta); Department of Ophthalmology 1st Faculty of Medicine of Charles University and Military University Hospital, Prague, Czech Republic (Pašta); Complejo Hospitalario Universitario de Santiago de Compostela, Santiago de Compostela, A Coruña, Spain (Touriño-Peralba).
Pablo de Arriba PalomeroORCID 0000-0002-5663-6302
Pedro Tañá-Rivero
Daniel Böhringer
Florian T A Kretz
Rosario Touriño-Peralba

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare 2 dispersive ophthalmic viscosurgical devices (OVDs), Z-HYALCOAT (investigational) and HEALON EndoCoat (control), with a 3-month postoperative follow-up.

settingMulticenter study conducted in 11 sites across Europe.

designProspective, randomized, masked, multicenter postmarket study.

methodsAdult participants having clear intraocular media excluding the presence of cataract and scheduled for uneventful age-related cataract removal by phacoemulsification and intraocular lens implantation in the capsular bag with sole administration of either investigational or control device as per randomization scheme were included in this study. Primary endpoint was the incidence of intraocular pressure (IOP) ≥30 mm Hg. Other endpoints included slitlamp observations, corneal endothelial cell density (ECD), surgeon-reported device functionality, and rate of adverse events and device deficiencies.

results242 participants were treated in this study (123 with the investigational OVD and 119 with the control OVD). In per-protocol population, 13 eyes (11.2%) from the investigational group and 19 (17.0%) from the control group reached an IOP equal to or higher than 30 mm Hg at 8 hours after device use. Slitlamp examinations performed up to 3 months did not reveal any relevant differences between the groups. ECD loss was also similar between the groups. Surgeon-reported OVD functionality was generally favorable and comparable for both devices.

conclusionsThis investigation proved the noninferiority of Z-HYALCOAT to HEALON EndoCoat in IOP spikes and showed the 2 devices to be highly similar in all evaluated aspects.

Indexed as

Chondroitin SulfatesHyaluronic AcidLens Implantation, IntraocularPhacoemulsificationViscosupplementsAgedAged, 80 and overCell CountDrug CombinationsEndothelium, CornealFemaleFollow-Up StudiesHumansIntraocular PressureMaleMiddle AgedChondroitin Sulfateschondroitin sulfate, sodium hyaluronate drug combinationDrug CombinationsHyaluronic AcidViscosupplements

Identifiers

PMID41283760
PMCPMC12998774

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.