Evidence map›Paper›PMID 41281563›Full record

ArticleFrontiers in neurology2025

Assessment of a biometric shirt for sleep body position identification in epilepsy.

Emmanuelle Nguyen, Manon Robert, Tian Yue Ding, Oumayma Gharbi, Amirhossein Jahani, Jérôme St-Jean, Claudia Rodriguez, Isabel Sarzo Wabi, Daniel Alejandro Galindo Lazo, Dang Khoa Nguyen and 1 more

Abstract read
In one paragraph

Article in Frontiers in neurology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Emmanuelle NguyenResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Manon RobertResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Tian Yue DingResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Oumayma GharbiResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Amirhossein JahaniResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Jérôme St-JeanResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Claudia RodriguezResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Isabel Sarzo WabiResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Daniel Alejandro Galindo LazoResearch Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Dang Khoa Nguyen *Research Centre of the University of Montreal Health Centre, Montreal, QC, Canada.
Elie Bou Assi *Research Centre of the University of Montreal Health Centre, Montreal, QC, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Patients with uncontrolled epilepsy are at increased risk of sudden unexpected death in epilepsy (SUDEP). Evidence suggests that sleeping prone or being in a prone position after a seizure may increase the risk of SUDEP. A few wearable devices have the potential to track sleeping habits. These devices could eventually be used to screen patients with epilepsy with a tendency to sleep in a prone position, allowing interventions such as sleep training to influence an ideal sleep position. Additionally, they could continuously monitor body positioning, allowing for responsive alarms and/or interventions when necessary. In this study, we prospectively assessed the accuracy of the Hexoskin biometric shirt algorithm in identifying sleep body positions. Methods: Patients were recruited at the University of Montreal Health Center (CHUM) epilepsy monitoring unit and were asked to wear the Hexoskin biometric shirt. A built-in algorithm identified prone, supine, right, left, or sitting/standing body positions using an accelerometer. Sleeping positions predicted by the algorithm were compared to "true" values collected via blind simultaneous video analysis. Results: Across 10 patients and 347 h of sleep analyzed, 65% of prone, 75% of supine, 94% of right lateral decubitus, 81% of left lateral decubitus, and 65% of sitting/standing positions were correctly classified by the Hexoskin algorithm. Balanced accuracy was 0.76 and weighted F1-score was 0.85. Conclusion: Our results show promise in the use of the Hexoskin shirt for detecting sleep positions. Optimizing performance in identifying prone sleep could enhance its clinical utility for monitoring patients with epilepsy.

Indexed as

body position trackingepilepsyHexoskinprone sleepingsleep positionSUDEPwearable devices

Identifiers

PMID41281563
PMCPMC12634538

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.