Evidence map›Paper›PMID 41276561›Full record

ArticleScientific reports2025

Modeling and integration of rooftop photovoltaic systems for sustainable energy access in public sector buildings in diverse climates.

Salman Habib, Muhammad Tamoor, Muhammad Majid Gulzar, Paris ZakaUllah, Ali Faisal Murtaza, Talal Alharbi

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Salman HabibDepartment of Control & Instrumentation Engineering, King Fahd University of Petroleum & Minerals, Dhahran, 31261, Saudi Arabia. salman.habib@kfupm.edu.sa.
Muhammad TamoorDepartment of Electrical and Energy Engineering, University of Rasul, Mandi Bahauddin, 50400, Pakistan.
Muhammad Majid GulzarDepartment of Control & Instrumentation Engineering, King Fahd University of Petroleum & Minerals, Dhahran, 31261, Saudi Arabia.
Paris ZakaUllahGovernment College University Faisalabad, Faisalabad, 38000, Pakistan.
Ali Faisal MurtazaDepartment of Electrical Engineering, College of Engineering, Qassim University, Buraydah, 52571, Saudi Arabia.
Talal AlharbiDepartment of Electrical Engineering, College of Engineering, Qassim University, Buraydah, 52571, Saudi Arabia. aTalal@qu.edu.sa.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The paper presents a comprehensive technical evaluation of grid-connected rooftop solar photovoltaic (PV) systems installed at two public sector buildings located in climatically diverse regions. The primary objective is to maximize the energy output of each PV system, which has been designed and optimized based on the locally-constrained conditions and the resource availability. Proposed location (PL-1) situated in a semi-arid region, was simulated using Aurora Solar, while PL-2, situated in a hilly region, was modeled with PVSYST. At PL-1, a 417.96 kWp system has been installed, estimated to generate around 594.743 MWh of energy annually, offsetting 95.52% of the building's annual energy consumption with a performance ratio (PR) of 82.6%. Similarly, PL-2 has a 63.2 kWp system, which is projected to produce 93.76 MWh, with a predicted PR of 80.1%. Under a degradation rate of 1%, the anticipated lifetime energy output is 13.214 GWh and 2.081 GWh, respectively. Environmental impact research indicates that each system achieves a carbon payback time of just 42 days, with cumulative CO₂ offsets of approximately 6606.96 metric tons (PL-1) and 1040.367 metric tons (PL-2) throughout their operational lifespan. A sensitivity analysis of degradation rates, energy output variations, and emission factor of grid emphasises the systems' resilience across diverse operational conditions. The economic evaluations show that PV systems installed at PL-1 and PL-2 have LCOE of 9.54 PKR/kWh and 9.37 PKR/kWh and payback period of around 3.27 and 3.39 years respectively, hence confirming their long-term economic sustainability. The findings validate that the implementation of rooftop photovoltaic systems in public sector buildings is both technically and economically feasible, with a combination of tailored modeling, solar resource assessment in specific locations, and a net metering policy being crucial for optimal renewable energy integration within national energy policy framework.

Indexed as

LCOERooftop photovoltaic systemSensitivity analysisSmart CitiesSmart GridSustainable energySystem losses

Identifiers

PMID41276561
PMCPMC12698681

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.