Evidence map›Paper›PMID 41275031›Full record

ArticleAnnals of biomedical engineering2026

False Lumen Haemodynamics in Type B Aortic Dissection: An in Vitro Study Using PIV and Patient-Specific Flexible Phantoms.

A Koulogiannis, Q Li, S Homer-Vanniasinkam, V Diaz-Zuccarini, S Balabani

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

A KoulogiannisDepartment of Mechanical Engineering, University College London (UCL), London, UK.
Q LiDepartment of Mechanical Engineering, University College London (UCL), London, UK.
S Homer-VanniasinkamDepartment of Mechanical Engineering, University College London (UCL), London, UK.
V Diaz-ZuccariniDepartment of Mechanical Engineering, University College London (UCL), London, UK.
S BalabaniDepartment of Mechanical Engineering, University College London (UCL), London, UK. s.balabani@ucl.ac.uk.ORCID http://orcid.org/0000-0002-6287-1106

Funding

Biotechnology and Biological Sciences Research Council BB/X005062/1British Heart Foundation NH/20/1/34705Engineering and Physical Sciences Research Council EP/W00481X/1University College London UCL BBSRC IIAWellcome TrustWellcome Trust 203145Z/16/Z
6 · The paper itself

Abstract

Aortic dissection (AD) is a catastrophic vascular pathology caused by delamination of the vascular wall and the formation of a false lumen. False lumen haemodynamics is a key determinant of aneurysmal growth, rupture, and thrombosis. Quantifying the haemodynamics in the false lumen can provide markers to predict these events and stratify patient risk. While such metrics can be extracted from numerical simulations or imaging modalities such as 4D flow MR, high-resolution experimental data are needed to validate them. The present study provides an in vitro characterization of the flow inside the false lumen of a type B aortic dissection using a patient-specific flexible phantom and Particle Image Velocimetry. A mock circulatory loop imposing patient-specific flow waveforms at the inlet and outlets of the aortic phantom and a refractive index matching blood analog were employed. Time-resolved measurements of the velocity field in four selected planes of the false lumen were acquired. Compared against our previous work on the same dissection assuming rigid walls, the results demonstrate the impact of wall compliance on the flow in the false lumen. They revealed the generation of a jet during the systolic phase that enters the false lumen through the primary tear and impinging on the opposite wall with high velocity, generating a strong rotational flow therein. During the diastolic phase, a reversal of the flow was observed generating multiple vortical structures both inside the true and false lumen. Haemodynamic markers such as false lumen ejection fraction were calculated and compared with clinical measurements. The results provide an insight on AD haemodynamics and highlight the potential of this in vitro method as a validation tool for simulations, as well as to physically test interventions in vitro.

Indexed as

Aortic AneurysmAortic DissectionHemodynamicsModels, CardiovascularPhantoms, ImagingHumansAortic dissectionFalse lumenFlexible phantomsHaemodynamicsParticle image velocimetryPatient-specific analyses

Identifiers

PMID41275031
PMCPMC12852207

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.