Evidence map›Paper›PMID 41272933›Full record

ArticleJournal of applied clinical medical physics2025

Comparative evaluation of image-guided radiation therapy (IGRT)-based dose calculation accuracy using cone-beam, megavoltage, and kilovoltage CT modalities.

Sirawit Saobai, Anirut Watcharawipha, Somsak Wanwilairat, Warit Thongsuk, Wannapha Nobnop

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sirawit SaobaiMedical Physics Program, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.
Anirut WatcharawiphaDivision of Radiation Oncology, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.
Somsak WanwilairatDivision of Radiation Oncology, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.
Warit ThongsukDivision of Radiation Oncology, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.ORCID https://orcid.org/0000-0002-8350-1518
Wannapha NobnopDivision of Radiation Oncology, Department of Radiology, Faculty of Medicine, ChiangMai University, Chiang Mai, Thailand.ORCID https://orcid.org/0000-0002-5266-2845

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluates the dosimetric accuracy of three image-guided radiotherapy (IGRT) imaging modalities, cone-beam computed tomography (CBCT), megavoltage computed tomography (MVCT), and image-guided kilovoltage computed tomography (IG-kVCT), using modality-specific HU-to-density (HU-D) calibrations. Dose calculations from IGRT images were compared to computed tomography simulation (CT-sim) references in phantoms and validated against measurements from head and neck and prostate patient plans to assess the feasibility of each modality for precise dose calculation in adaptive radiotherapy (ART).

methodsTwo phantoms, the Tomo phantom HE and CIRS Thorax phantom, were used for HU-to-density (HU-D) calibration. IGRT images were acquired using Elekta Synergy XVI (CBCT) and Radixact X9 (MVCT and IG-kVCT), and calibration curves were generated for each modality. Dose distributions calculated from IGRT images were then compared with those from CT-sim in phantom studies. For measurement-based evaluation, 10 patient plans (head and neck and prostate cases) were delivered to a phantom and measured using the ArcCHECK system, and recalculated doses on CT-sim and IGRT images were compared to the measured doses. Gamma analysis was performed to assess dosimetric accuracy.

resultsIG-kVCT showed the closest agreement with CT-sim, achieving gamma passing rates (GPR) of 99.8% ± 0.3% for 3%/3 mm and 98.5% ± 0.7% for 3%/2 mm criteria, with dose differences below 1%. CBCT and MVCT demonstrated slightly lower accuracy, with GPRs of 97.2% ± 1.1% and 96.5% ± 1.3% for 3%/3 mm, respectively, and dose differences up to 2%. Similar trends were observed when compared to measured doses. All IGRT modalities showed clinically acceptable agreement, and no statistically significant differences were found between CT-sim and any IGRT modality.

conclusionAll three IGRT modalities demonstrated clinically acceptable accuracy for adaptive dose calculation with modality-specific HU-D calibration curves.

Indexed as

Cone-Beam Computed TomographyHead and Neck NeoplasmsPhantoms, ImagingProstatic NeoplasmsRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedCalibrationHumansImage Processing, Computer-AssistedMaleRadiotherapy DosageRadiotherapy, Intensity-Modulatedcone‐beam CT (CBCT)dose re‐calculationHounsfield unit‐to‐density calibration (HU‐D)IG‐kVCTimage‐guided radiation therapy (IGRT)MVCT

Identifiers

PMID41272933
PMCPMC12638267

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.