Evidence map›Paper›PMID 41272914›Full record

ArticleBMC biomedical engineering2025

IMU-based joint axis identification method for arbitrary joints in OpenSim - a simulation study.

Iris Wechsler, Julian Shanbhag, Sandro Wartzack, Anne D Koelewijn, Jörg Miehling

Abstract read
In one paragraph

Article in BMC biomedical engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Iris WechslerEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstrasse 9, 91058, Erlangen, Germany. wechsler@mfk.fau.de.
Julian ShanbhagEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstrasse 9, 91058, Erlangen, Germany.
Sandro WartzackEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstrasse 9, 91058, Erlangen, Germany.
Anne D KoelewijnMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Carl-Thiersch-Strasse 2b, 91052, Erlangen, Germany.
Jörg MiehlingEngineering Design, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstrasse 9, 91058, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In musculoskeletal simulation, individualized joint axes enhance the accuracy and reliability of kinematic and kinetic simulation results. We investigated the correctness and performance of an analytical method for identifying the instantaneous axis of rotation between two bodies based on motion data in OpenSim. The instantaneous center of rotation is the point at which two bodies have the same velocity. The relative linear and angular velocity between the two bodies, as well as their relative position to each another, are required as inputs to calculate it. Using the instantaneous center of rotation, fixed or moving joint centers of rotation can be identified. To prove the general applicability of the method, the instantaneous centers of rotation of a revolute joint of a simple double pendulum model and the hip and knee joint of a more complex musculoskeletal model were investigated. The hip joint is defined as a ball joint. The knee joint is defined as an OpenSim custom joint which describes the motion of the child segment in relation to the parent segment as a function of generalized coordinates. To verify the correctness of the approach in OpenSim, the moving centers of rotation were calculated using synthetic noisefree data. The results were compared to the implementation of the respective joints in the model which act as the ground truth. White Gaussian noise was added to the synthetic data to analyze its effect on the quality of the calculated centers of rotation. We were able to correctly identify the center of rotation of each joint using noisefree data. In the case of noisy data, joint centers of rotation can be determined by applying additional filtering or optimization methods to the calculated instantaneous centers of rotation. Consequently, we are able to determine the center of rotation for arbitrary joints based on noisy synthetic data. This approach is applicable for both fixed and moving centers of rotation which distinguishes it from commonly used methods in the field of biomechanical simulation.

Indexed as

Biomechanical modeling and simulationInstantaneous axis of rotationJoint axis identificationMeasurement noiseModel individualization

Identifiers

PMID41272914
PMCPMC12639932

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.