Evidence map›Paper›PMID 41272255›Full record

ArticleScientific reports2025

Effect of metallic sealant thickness on leak arrest and composite repair performance in pipeline systems.

Meshari Mohammed Alharthi, Ibrahim A Alnaser

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Meshari Mohammed AlharthiMechanical Engineering Department, College of Engineering, King Saud University, Riyadh, 11421, Saudi Arabia.
Ibrahim A AlnaserMechanical Engineering Department, College of Engineering, King Saud University, Riyadh, 11421, Saudi Arabia. ianaser@ksu.edu.sa.

Funding

Kind Saud University ORF-2025-597
6 · The paper itself

Abstract

This study investigates the combined effect of metallic sealant thickness and composite laminate configuration on the structural performance of pipeline repair systems. A total of 63 experiments were conducted on through-wall defects with diameters of 10.2 mm, 15.2 mm, and 25.4 mm diameters, three metallic sealant thicknesses (3.5 mm, 7 mm, and 10.5 mm) were evaluating under both dry and wet conditions. Additionally, two- and four-layer fiberglass composite overwraps were applied to assess their influence on pressure retention and energy release rate. Results showed that increasing sealant thickness significantly enhanced failure leak pressure, particularly in wet environments, where thinner sealants underperformed. The 10.5 mm thickness consistently delivered the best sealing capability across all conditions. Composite repairs improved performance further, with four-layer systems providing the highest-pressure resistance. However, only a marginal increase in interfacial energy release rate was observed, suggesting diminishing returns beyond a certain layer count. Experimental leak pressures exceeded theoretical predictions from ISO/TS 24,817, indicating the need to update current models. This research provides practical guidance for selecting optimal sealant thicknesses and laminate configurations based on defect size and environmental conditions, offering a more reliable, in-service repair solution for pipelines in the oil and gas industry.

Indexed as

Composite repairFailure leak pressureFracture mechanicsMetallic sealantPipeline defects

Identifiers

PMID41272255
PMCPMC12638894

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.