ArticleScientific reports2025
Bifurcation-based wide-range vacuum pressure micro-sensor.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In this paper, we present a high-performance, low-to-medium vacuum pressure sensor operating in bifurcation-switching mode, based on an electrostatically actuated resonant microplate supported by two microcantilever beams. The proposed micro-sensor is based on detecting a shift in the response frequency associated with the pressure variation. The sensing principle relies on tracking the jump frequency values, operating near the pull-in voltage, and measuring the frequency shift in a wide pressure range. The dynamic response and the frequency shift of the microdevice were captured and analyzed through both optical (Laser Doppler Vibrometer) and electrical (Lock-in Amplifier) characterization setups at various pressure levels. We demonstrate that by driving the first mode nonlinearly and electrostatically near the pull-in phenomenon (VDC= 55.5 V), a high-frequency shift due to pressure change is achieved. Based on this sensing mechanism, a sensitivity S of 61 ppm/Torr (VDC = 15 V and VAC= 30 V) was obtained for a pressure range of 300–500 Torr. Moreover, increasing VDC to 20 V, the sensitivity was increased by sixfold. Additionally, for medium-vacuum pressure (0.5–10 Torr) and at low DC voltage of 0.5 V, the microsensor reached a high sensitivity of 10,000 ppm/Torr, which is significantly higher than that reported in the literature. Near atmospheric pressure, the proposed microsensor also demonstrated a high sensitivity of 74 ppm/Torr and a nonlinearity < 2%. Hence, these results establish the bifurcation-switching mode pressure sensor as a new class of zero-active-power (such as electrothermal actuation) consumption devices that can convert pressure into frequency-switching dynamics, offering high performance in terms of sensitivity, linearity, and other key sensing metrics.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.