Evidence map›Paper›PMID 41272046›Full record

ArticleScientific reports2025

Biomechanical evaluation of a lower-limb implant model under gait and stumbling conditions using finite element analysis.

Guerchouh Nawel, Sahli Abderahmane, Moulgada Abdelmadjid, Zagane Mohammed El Sallah, Murat Yaylacı, Şevval Öztürk, Boudjemaa Ismail, Ecren Uzun Yaylacı, Ayberk Dizdar, Yılmaz Güvercin

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Guerchouh NawelDepartment of Mechanical Engineering, University of Tiaret, 14000, Tiaret, Algeria.
Sahli AbderahmaneLaboratory Mechanics Physics of Materials, Department of Mechanical Engineering, University of Sidi Bel Abbes, 22000, Sidi Bel Abbes, Algeria.
Moulgada AbdelmadjidDepartment of Mechanical Engineering, University of Tiaret, 14000, Tiaret, Algeria.
Zagane Mohammed El SallahDepartment of Mechanical Engineering, University of Tiaret, 14000, Tiaret, Algeria.
Murat YaylacıBiomedical Engineering MSc Program, Recep Tayyip Erdogan University, 53100, Rize, Turkey. murat.yaylaci@erdogan.edu.tr.
Şevval ÖztürkDepartment of Civil Engineering, Recep Tayyip Erdogan University, 53100, Rize, Turkey.
Boudjemaa IsmailGaseous Fuels and Environment Laboratory, Department of Mechanical Engineering, University of Sciences and Technology of Oran Mohamed Boudiaf (USTO-MB), El Mnaouer, Bir El Djir, BP1505, 31000, Oran, Algeria.
Ecren Uzun YaylacıFaculty of Fisheries, Recep Tayyip Erdogan University, 53100, Rize, Turkey.
Ayberk DizdarDepartment of Biomedical Engineering, Kocaeli University, Kocaeli, 41380, Turkey.
Yılmaz GüvercinDepartment of Orthopaedic and Traumatology, Trabzon Kanuni Training and Research Hospital, 61250, Trabzon, Turkey.

Funding

Recep Tayyip Erdoğan University Development Foundation 02025007002613Recep Tayyip Erdoğan University Scientific Research Projects Unit FBI-2024-1589
6 · The paper itself

Abstract

Addressing the needs of patients with lower-limb amputations remains a complex challenge due to the unique biomechanical and personal requirements of each individual. An effective prosthesis must be carefully adapted to ensure optimal comfort, flexibility, and stability. This study presents a finite element analysis aimed at developing an optimal implant model evaluated during lower-limb locomotion, specifically under two scenarios: normal walking and stumbling. The stumbling phase presents increased biomechanical demands, requiring greater balance and structural resilience. The analysis focuses on the influence of varying the liner's Young's modulus on the distribution of equivalent Von Mises stresses in the femur and implant. Additionally, the study investigates contact pressure and longitudinal shear stress distributions on the liner, providing a comprehensive comparison across all cases. The findings contribute valuable insights toward the optimization of prosthetic design for improved comfort and safety in everyday movement.

Indexed as

Artificial LimbsGaitLower ExtremityBiomechanical PhenomenaFemurFinite Element AnalysisHumansProsthesis DesignStress, MechanicalWalkingCPRESSCSHEARFinite element methodLinerNormal walkingStumbling

Identifiers

PMID41272046
PMCPMC12638921

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.