ArticleScientific reports2025
Active line model identification protection based on characteristic frequency phase for dual-end weakly-fed AC system.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The large-scale integration of renewable energy into the grid through flexible DC transmission systems has become an inevitable trend in power delivery. Model-based protection schemes, unaffected by power source characteristics, have been widely applied in renewable energy grid-connected systems. However, in a dual-end weakly-fed AC system, this results in significant adaptability issues with existing model-based protection schemes. To address this, this paper proposes an active line model identification protection based on characteristic frequency phase for dual-end weakly-fed AC system. First, this paper investigates the adaptability of conventional model recognition principles in a the dual-ended weakly fed AC system. Building on this, a control strategy is proposed that utilizes Modular Multilevel Converters (MMC) for the injection of characteristic frequency signals. The criteria for selecting the injected signals and their extraction methods are outlined. Subsequently, an analysis of the line model under injected characteristic frequency signals is presented, focusing on the differences in the phase characteristics of the line model at various fault locations. Finally, in the PSCAD/EMTDC electromagnetic simulation platform simulation, combined with empirical wavelet transform and Prony (EWT-Prony) algorithm to extract the characteristic frequency phase of the line model, the effectiveness of the proposed protection scheme is verified. The results demonstrate that the proposed scheme can withstand high fault impedance (300Ω) and noise interference (25 dB), confirming its robustness and reliability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.