ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2026
Optically-Coupled X-Ray Computed Laminography System for High-Speed Inspection of Lithium-Ion Batteries.
Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Prior Image-Guided Adaptive-Weighted Relative Total Variation for Sparse-View Computed Laminography of Plate-like Objects.Sensors (Basel, Switzerland) · 2026Article
- Optically-Coupled X-Ray Computed Laminography System for High-Speed Inspection of Lithium-Ion Batteries.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Conventional X-ray computed tomography systems for microstructure inspection typically employ a geometrically magnified imaging setup, requiring a micro-focus X-ray source to mitigate image blurring caused by a finite focal spot size. However, due to its low output power, the micro-focus X-ray source results in prolonged image acquisition times. This study presents a novel optically-coupled X-ray computed laminography system for high-speed inspection. In the proposed system, a scintillator is placed in contact with an object, effectively minimizing image blurring despite the use of an X-ray source with a large focal spot. Consequently, a high-power X-ray tube can be employed without compromising spatial resolution, leading to a significant reduction in scan time. Modulation transfer function analysis confirms that a spatial resolution of 38 µm is achieved using a high-power (400 W) X-ray tube with a 400 µm focal spot. In addition, high-quality 3D imaging of lithium-ion batteries (LIBs) is demonstrated with a scan time as low as 2 s and a contrast-to-noise ratio exceeding 3. By overcoming the trade-off between the spatial resolution and the scan time in X-ray imaging, the proposed system enables high-throughput in-line inspection of mass-produced LIBs.