In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jaeyoung ImDepartment of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Jun HeoDepartment of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Seunguk CheonDepartment of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Jichan KimDepartment of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
Sung Oh ChoDepartment of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.ORCID https://orcid.org/0000-0002-5441-3244

Funding

Radiation Convergence Industry Support Program N01251190Research and Development Special Zone Promotion Project, Ministry of Science and ICT N01251219
6 · The paper itself

Abstract

Conventional X-ray computed tomography systems for microstructure inspection typically employ a geometrically magnified imaging setup, requiring a micro-focus X-ray source to mitigate image blurring caused by a finite focal spot size. However, due to its low output power, the micro-focus X-ray source results in prolonged image acquisition times. This study presents a novel optically-coupled X-ray computed laminography system for high-speed inspection. In the proposed system, a scintillator is placed in contact with an object, effectively minimizing image blurring despite the use of an X-ray source with a large focal spot. Consequently, a high-power X-ray tube can be employed without compromising spatial resolution, leading to a significant reduction in scan time. Modulation transfer function analysis confirms that a spatial resolution of 38 µm is achieved using a high-power (400 W) X-ray tube with a 400 µm focal spot. In addition, high-quality 3D imaging of lithium-ion batteries (LIBs) is demonstrated with a scan time as low as 2 s and a contrast-to-noise ratio exceeding 3. By overcoming the trade-off between the spatial resolution and the scan time in X-ray imaging, the proposed system enables high-throughput in-line inspection of mass-produced LIBs.

Indexed as

high‐speed inspectionlithium‐ion batteryoptical magnificationX‐ray computed laminography

Identifiers

PMID41268692
PMCPMC12866757

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked