Evidence map›Paper›PMID 41265481›Full record

ArticleBone & joint research2025

Arthroscopic cam resection reduces femoroacetabular contact pressure : a cadaver study.

Pedro Dantas, Sérgio B Gonçalves, Sérgio R Gonçalves, Vasco Mascarenhas, Jorge Martins, Miguel Tavares da Silva, José Guimarães Consciência

Abstract read
In one paragraph

Article in Bone & joint research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Pedro DantasNOVA Medical School, Lisbon, Portugal.
Sérgio B GonçalvesIDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
Sérgio R GonçalvesDepartment of Orthopaedic Surgery, Hospital CUF Descobertas, Lisbon, Portugal.
Vasco MascarenhasMusculoskeletal Imaging Unit, Hospital da Luz, Lisbon, Portugal.
Jorge MartinsIDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
Miguel Tavares da SilvaIDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.
José Guimarães ConsciênciaNOVA Medical School, Lisbon, Portugal.

Funding

CUF
6 · The paper itself

Abstract

Aims: Arthroscopic cam resection in femoroacetabular impingement syndrome leads to clinical improvement, but biomechanical studies on the effect of surgical intervention are scarce. In this study, we compared the femoroacetabular contact pressure (CP) in an intact cam morphology and after arthroscopic cam resection. The hypothesis was that arthroscopic cam resection decreases the femoroacetabular CP. Methods: A cadaveric study was performed on nine hips with a cam morphology (α angle > 60°). CP was assessed using a new hip-specific device and an intracranial pressure (ICP) sensor. These evaluations were performed during hip arthroscopy, in the intact joint and after cam resection, with the joint in different positions. These measurements were normalized and reported as a percentage of the native intact joint. Results: A statistically significant difference in the mean CP measured with the hip-specific device was observed before and after cam osteoplasty at 0° (41.2% (SD 29.7%); p = 0.014), 30° (54.5% (SD 16.6%); p = 0.011), 60° (39.8% (SD 23.0%); p < 0.001), 80° of flexion (36.3% (SD 22.1%); p < 0.001), and 80° of flexion with 20° of internal rotation (26.0% (SD 22.4%); p < 0.001). The ICP sensor is very fragile and difficult to handle in hip arthroscopy. Consequently, we limited the evaluations using this sensor to five hips. A statistically significant difference in the CP was found before and after cam osteoplasty at 80° of flexion (57.6% (SD 29.1%); p = 0.004). Conclusion: This biomechanical study evaluated a new hip-specific device to intraoperatively measure the CP in arthroscopic surgery. It showed a significant decrease in the CP after arthroscopic cam resection with the joint in different positions. At 80° of flexion with 20° of internal rotation, a typical position to detect hip impingement, the CP was reduced to 26% after arthroscopic cam resection. The intraoperative measurement of CP provides surgeons with feedback to evaluate the effectiveness of the osteoplasty.

Identifiers

PMID41265481
PMCPMC12634145

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.