Evidence map›Paper›PMID 41262470›Full record

ArticleJournal of experimental orthopaedics2025

A single lateral hinge screw increased resistance to varus stress after medial closing wedge distal femoral osteotomy in a Sawbones model: A biomechanical analysis.

Benjamin J Main, Matthieu Ollivier, Pooyan Abbasi, Steven J Svoboda, James C Dreese, Jingyi Shao, Wiemi A Douoguih

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Benjamin J MainMedStar Lafayette Orthopaedic and Sports Medicine Center MedStar Washington Hospital Center Washington DC USA.ORCID https://orcid.org/0000-0002-7047-8857
Matthieu OllivierInstitut du Mouvement et de l'Appareil Locomoteur, Hospital Sainte-Marguerite Aix-Marseille Universite Marseille France.ORCID https://orcid.org/0009-0009-7025-2776
Pooyan AbbasiDepartment of Orthopaedic Surgery MedStar Union Memorial Hospital Baltimore Maryland USA.ORCID https://orcid.org/0000-0001-5587-7879
Steven J SvobodaMedStar Lafayette Orthopaedic and Sports Medicine Center MedStar Washington Hospital Center Washington DC USA.ORCID https://orcid.org/0000-0002-2212-6953
James C DreeseDepartment of Orthopaedic Surgery MedStar Union Memorial Hospital Baltimore Maryland USA.ORCID https://orcid.org/0000-0002-9595-8443
Jingyi ShaoDepartment of Orthopedic/Sports Medicine Research MedStar Health Research Institute Columbia Maryland USA.ORCID https://orcid.org/0009-0009-8434-6888
Wiemi A DouoguihMedStar Lafayette Orthopaedic and Sports Medicine Center MedStar Washington Hospital Center Washington DC USA.ORCID https://orcid.org/0000-0002-7822-2039

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the biomechanical effects of a lateral hinge screw on postoperative fracture after medial closing wedge distal femoral osteotomy (MCWDFO). It was hypothesized that adding a lateral hinge screw would significantly increase the failure strength of the hinge. Methods: Twelve Sawbone femurs were used for the study. A biplanar cut was made, a protective lateral hinge pin was placed, and a 5 mm-closing wedge osteotomy was performed in each specimen. After osteotomy, the hinge pin was removed in six specimens, and in the remaining six specimens, the hinge pin was replaced with a lateral hinge screw. A varus load was then applied utilizing a load frame in a single load-to-failure test. Failure was defined as the point just before a substantial drop in the force versus displacement curve. Nonparametric Wilcoxon rank-sum test was performed to compare maximum load and stiffness between the hinge screw and no hinge screw groups with Results: The maximum load to failure was significantly higher in the hinge screw group versus the control group, 440 ± 70 N versus 256 ± 107 N (mean ± standard deviation), respectively. Load to failure was 72% higher in the hinge screw group versus the no hinge screw group. No significant difference in stiffness was found between the groups. Conclusion: Using a Sawbone model, the current data showed that placement of a lateral hinge screw significantly increased resistance to varus stress following MCWDFO compared with a construct having no screw. Additionally, no significant difference in stiffness was observed between the group with the hinge screw and the group without the screw. Further investigation should assess the clinical benefit of a hinge screw in reducing surgical morbidity during the postoperative period for patients undergoing a distal femoral osteotomy. Level of Evidence: N/A.

Indexed as

distal femoral osteotomyhinge fracturelateral hinge fractureosteotomy

Identifiers

PMID41262470
PMCPMC12626272

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.