ArticleLight, science & applications2025
Open-source sub-nanometer stabilization system for super-resolution fluorescence microscopy.
Article in Light, science & applications, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Localization of single molecules with structured illumination and structured detection.Light, science & applications · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Recent advances in fluorescence nanoscopy have pushed resolution to the 1-10 nm range, enabling the direct visualization of individual molecules even in crowded biological environments. Achieving this level of precision requires rigorous sample drift control. Techniques such as MINFLUX and RASTMIN, which rely on keeping the sample fixed within an excitation pattern, demand active drift correction to achieve their theoretical nanometer-scale resolution limits. Here, we present an active stabilization system for super-resolution microscopy that delivers sub-nm precision for hours. Featuring a simple optical design, the system can be added as a separate module to any fluorescence microscope. We also provide an open-source control software including a user-friendly graphical interface readily adaptable to different setups. We demonstrate the adaptability and performance of the stabilization system with p-MINFLUX and RASTMIN measurements performed in two different setups, reaching the theoretical Cramér-Rao Bound and resolving ~10 nm distances within DNA origami structures.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.