Evidence map›Paper›PMID 41259737›Full record

ArticleAnalytical chemistry2025

Comparative Analysis of Sample Loop and Counting Bead-Based Methods for Size-Dependent Bias in Flow Cytometry.

Hye Ji Shin, Subeen Kim, Minjeong Kwak, Inchul Yang, Sang-Ryoul Park, Jihwan Song, Ji Youn Lee

Abstract readComparative Study
In one paragraph

Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hye Ji ShinBiometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea.ORCID 0009-0000-0896-3184
Subeen KimDepartment of Mechanical Engineering, Hanbat National University, 125, Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea.
Minjeong KwakNanobio Measurement Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea.
Inchul YangBiometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea.ORCID 0000-0001-6756-3893
Sang-Ryoul ParkBiometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea.ORCID 0000-0003-4143-7906
Jihwan SongDepartment of Mechanical Engineering, Hanbat National University, 125, Dongseo-daero, Yuseong-gu, Daejeon 34158, Republic of Korea.
Ji Youn LeeBiometrology Group, Division of Biomedical Metrology, Korea Research Institute of Standards and Science, 267 Gajeong-ro, Yuseong-gu, Daejeon 34113, Republic of Korea.ORCID 0000-0002-4288-4559

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Reliable and accurate particle number concentration measurements are essential across various fields, including clinical diagnostics, environmental monitoring, and industrial applications. Flow cytometry is widely used for these measurements, where the use of counting beads is a common approach. However, this method can introduce size-dependent bias when the target particles differ in size from the counting beads. To evaluate size-dependent bias, this study systematically compares the conventional counting bead-based method with a sample loop-based method that relies on total counting with a defined sample volume. Experimental results show that while both methods yield similar concentrations for beads of comparable size, discrepancies arise when there are significant size differences between the counting beads and target particles. To investigate the cause of this bias, simulations based on force balance analysis were conducted, revealing that larger beads experience stronger forces that facilitate their movement toward the detection area, while smaller beads are more influenced by Brownian motion, which impedes their overall motion. These findings provide a mechanistic explanation for the observed size-dependent bias, confirming that differences in hydrodynamic behavior contribute to variations in bead distribution and motion. By using the sample loop method, which minimizes size-dependent bias, and employing an empirical equation derived from the results, this study offers a reliable approach for predicting and mitigating bias in particle concentration measurements. This work therefore contributes to the development of more precise and traceable methods for particle number concentration measurement, with implications for a wide range of biological and industrial applications.

Indexed as

Flow CytometryMicrospheresHydrodynamicsParticle Size

Identifiers

PMID41259737
PMCPMC12676513

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials